S7-1200 G1 by SIEMENS

CPU 1215 FC, DC/DC/RLY,14DI/10DO/2AI/2AO-6ES7215-1HF40-0XB0

Learn more
In stock

Description

SIMATIC S7-1200F, CPU 1215 FC, compact CPU, DC/DC/relay, 2 PROFINET ports, onboard I/O: 14 DI 24 V DC; 10 DO relay 2 A, 2 AI 0-10 V DC, 2 AO 0-20 mA DC, power supply: DC 20.4-28.8 V DC, program/data memory 250 KB

General information

Product type designation CPU 1215FC DC/DC/relay

Firmware version V4.7

Engineering with

● Programming package STEP 7 V20 or higher

Supply voltage

Rated value (DC)

● 24 V DC Yes

permissible range, lower limit (DC) 20.4 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Load voltage L+

● Rated value (DC) 24 V

● permissible range, lower limit (DC) 20.4 V

● permissible range, upper limit (DC) 28.8 V

Input current

Current consumption (rated value) 500 mA; CPU only

Current consumption, max. 1 500 mA; CPU with all expansion modules

Inrush current, max. 12 A; at 28.8 V DC

I²t 0.5 A²·s

Output current

for backplane bus (5 V DC), max. 1 600 mA; Max. 5 V DC for SM and CM

Encoder supply

24 V encoder supply

● 24 V L+ minus 4 V DC min.

Power loss

Power loss, typ. 12 W

Storage

Work memory

● Integrated 250 kbyte

Load memory

● Integrated 4 Mbyte

● Plug-in (SIMATIC Memory Card), max. with SIMATIC memory card

Backup

● present Yes

● maintenance-free Yes

● without battery Yes

CPU processing times

for bit operations, typ. 0.08 µs; / instruction

for word operations, typ. 1.7 µs; / instruction

for floating point arithmetic, typ. 2.3 µs; / instruction

CPU-blocks

Number of blocks (total) DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used

OB

● Number, max. Limited only by RAM for code

Data areas and their retentivity

Retentive data area (incl. timers, counters, flags), max. 14 kbyte

Flag

● Size, max. 8 kbyte; Size of bit memory address area

Local data

● per priority class, max. 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB

Address area

Process image

● Inputs, adjustable 1 kbyte

● Outputs, adjustable 1 kbyte

Hardware configuration

Number of modules per system, max. 3 comm. modules, 1 signal board, 8 signal modules

● number of expansion boards (SB, CB, BB) 1

● number of signal modules (SM) 8

● number of communications modules (CM) 3

Time of day

Clock

● Hardware clock (real-time) Yes

● Backup time 480 h; Typical

● Deviation per day, max. ±60 s/month at 25 °C

Digital inputs

Number of digital inputs 14; Integrated

● of which inputs usable for technological functions 6; HSC (High Speed Counting)

Sourcing/sinking input Yes

Number of simultaneously controllable inputs

all mounting positions

— up to 40 °C, max. 14

Input voltage

● Rated value (DC) 24 V

● for signal “0” 5 V DC at 1 mA

● for signal “1” 15 V DC at 2.5 mA

Input delay (for rated value of input voltage)

for standard inputs

— parameterizable Yes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms

— at “0” to “1”, min. 0.2 ms

— at “0” to “1”, max. 12.8 ms

for interrupt inputs

— parameterizable Yes

for technological functions

— parameterizable Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz

Cable length

● shielded, max. 500 m; 50 m for technological functions

● unshielded, max. 300 m; for technological functions: No

Digital outputs

Number of digital outputs 10; Relays

Switching capacity of the outputs

● with resistive load, max. 2 A

● on lamp load, max. 30 W with DC, 200 W with AC

Output delay with resistive load

● “0” to “1”, max. 10 ms; max.

● “1” to “0”, max. 10 ms; max.

Relay outputs

● Number of relay outputs 10

● Number of operating cycles, max. mechanically 10 million, at rated load voltage 100 000

Cable length

● shielded, max. 500 m

● unshielded, max. 150 m

Analog inputs

Number of analog inputs 2

Input ranges

● Voltage Yes

Input ranges (rated values), voltages

● 0 to +10 V Yes

— Input resistance (0 to 10 V) ≥100k ohms

Cable length

● shielded, max. 100 m; twisted and shielded

Analog outputs

Number of analog outputs 2

Output ranges, current

● 0 to 20 mA Yes

Analog value generation for the inputs

Integration and conversion time/resolution per channel

● Resolution with overrange (bit including sign), max. 10 bit

● Integration time, parameterizable Yes

● Conversion time (per channel) 625 µs

Analog value generation for the outputs

Integration and conversion time/resolution per channel

● Resolution with overrange (bit including sign), max. 10 bit

Encoder

Connectable encoders

● 2-wire sensor Yes

Interfaces

Number of PROFINET interfaces 1

1. Interface

Interface type PROFINET

Isolated Yes

automatic detection of transmission rate Yes

Autonegotiation Yes

Autocrossing Yes

Interface types

● RJ 45 (Ethernet) Yes

● Number of ports 2

● integrated switch Yes

Protocols

● PROFINET IO Controller Yes

● PROFINET IO Device Yes

● SIMATIC communication Yes

● Open IE communication Yes; Optionally also encrypted

● Web server Yes

● Media redundancy Yes

PROFINET IO Controller

● Transmission rate, max. 100 Mbit/s

Services

— PG/OP communication Yes; encryption with TLS V1.3 pre-selected

— Isochronous mode No

— IRT No

— PROFIenergy No

— Prioritized startup Yes

— Number of IO devices with prioritized startup, max. 16

— Number of connectable IO Devices, max. 16

— Number of connectable IO Devices for RT, max. 16

— of which in line, max. 16

— Number of IO Devices that can be simultaneously activated/deactivated, max. 8

— Updating time