ET 200SP by SIEMENS

CPU 1512SP-1 PN, 400KB Prog., 2MB Data -6ES7512-1DM03-0AB0

INR 1
DATASHEET
In stock

Description

SIMATIC DP, CPU 1512SP-1 PN for ET 200SP, central processing unit with 400 KB work memory for program and 2 MB for data, 1st interface: PROFINET IRT with 3-port switch, 6 ns bit performance, including server module (6ES7193-6PA00-0AA0); SIMATIC Memory Card required, BusAdapter required for port 1 and 2

Product type designation CPU 1512SP-1 PN

HW functional status FS04

Firmware version V4.0

● FW update possible Yes

Product function

● I&M data Yes; I&M0 to I&M3

● Module swapping during operation (hot swapping) Yes; Multi-hot swapping

● Isochronous mode Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs

● SysLog Yes

Engineering with

● STEP 7 TIA Portal configurable/integrated from version V20 (FW V4.0) / V18 (FW V3.0) or higher; configurable with older TIA Portal versions as 6ES7 512-1DK01-0AB0

Configuration control

via dataset Yes

Control elements

Mode selector switch 1

Supply voltage

Rated value (DC) 24 V

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Mains buffering

● Mains/voltage failure stored energy time 10 ms

Input current

Current consumption (rated value) 0.48 A

Current consumption, max. 0.7 A

Inrush current, max. 1.34 A; Rated value

I²t 0.3 A²·s

Power

Infeed power to the backplane bus 8.05 W

Power loss

Power loss, typ. 3.5 W

Storage

Number of slots for SIMATIC memory card 1

SIMATIC memory card required Yes

Work memory

● integrated (for program) 400 kbyte

● integrated (for data) 2 Mbyte

Load memory

● Plug-in (SIMATIC Memory Card), max. 32 Gbyte

Backup

● maintenance-free Yes

CPU processing times

for bit operations, typ. 6 ns

for word operations, typ. 7 ns

for fixed point arithmetic, typ. 9 ns

for floating point arithmetic, typ. 37 ns

CPU-blocks

Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs

DB

● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999

● Size, max. 1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB

FB

● Number range 0 ... 65 535

● Size, max. 400 kbyte

FC

● Number range 0 ... 65 535

● Size, max. 400 kbyte