ET 200SP by SEIMENS

CPU1515SP PC2 + HMI 512PT-6ES7677-2DB42-0GL0

INR 1
DATA SHEET
In stock

Description

SIMATIC ET 200SP Open Controller, CPU 1515SP PC2 + HMI 512PT, 8 GB RAM (basic device 6ES7677-2DB40-0AA0), 128 GB CFast with Windows 10 IoT Enterprise LTSC 2019 64-bit, S7-1500 Software Controller CPU 1505SP V2x and WinCC Runtime Advanced V17 preinstalled, with 512 PowerTags license; interfaces: 1x slot CFast, 1x slot SD/MMC, 1x connection for ET 200SP BusAdapter PROFINET, 1x 10/100/1000 Mbps Ethernet, 2x USB 3.0, 2x USB 2.0, 1x DisplayPort; documentation on CFast,

General information

Product type designation CPU 1515SP PC2

HW functional status from FS04

Firmware version V21.9

Engineering with

● STEP 7 TIA Portal configurable/integrated from version V17

Installed software

● Visualization WinCC Runtime Advanced V17

● Control S7-1500 Software Controller CPU 1505SP

Configuration control

via dataset Yes

Control elements

Mode selector switch 1

Supply voltage

Rated value (DC) 24 V

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Mains buffering

● Mains/voltage failure stored energy time 5 ms

Input current

Current consumption (rated value) 1.8 A; Full processor load, incl. ET 200SP modules and using USB

Current consumption (in no-load operation), typ. 0.5 A

Current consumption, max. 2.9 A

I²t 0.426 A²·s; with starting current inrush

Power

Active power input, max. 43 W; incl. ET 200SP modules and using USB

Infeed power to the backplane bus 8.75 W

Power loss

Power loss, typ. 15 W; without ET 200SP modules and without using USB

Processor

Processor type Intel Atom E3940, 1.6 GHz, 4 cores

Storage

Type of memory DDR3L

Main memory 8 GB RAM

CFast memory card Yes; 128 GB flash memory

SIMATIC memory card required No

Work memory

● integrated (for program) 1 Mbyte

● integrated (for data) 5 Mbyte

● integrated (for CPU function library of CPU Runtime) 20 Mbyte

Load memory

● integrated (on PC mass storage) 320 Mbyte

Backup

● with UPS Yes; all memory areas declared retentive

● with non-volatile memory Yes

CPU-blocks

Number of elements (total) 6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements

DB

● Number, max. 5 999; Number range: 1 to 65535

● Size, max. 5 Mbyte

FB

● Number, max. 5 998; Number range: 1 to 65535

● Size, max. 1 024 kbyte

FC

● Number, max. 5 999; Number range: 1 to 65535

● Size, max. 1 024 kbyte

OB

● Size, max. 1 024 kbyte

● Number of free cycle OBs 100

● Number of time alarm OBs 20

● Number of delay alarm OBs 20

● Number of cyclic interrupt OBs 20

● Number of process alarm OBs 50

● Number of DPV1 alarm OBs 3

● Number of isochronous mode OBs 1

● Number of technology synchronous alarm OBs 2

● Number of startup OBs 100

● Number of asynchronous error OBs 4

● Number of synchronous error OBs 2

● Number of diagnostic alarm OBs 1

Nesting depth

● per priority class 24

Counters, timers and their retentivity

S7 counter

● Number 2 048

Retentivity

— can be set Yes

IEC counter

● Number Any (only limited by the main memory)

Retentivity

— can be set Yes

S7 timer

● Number 2 048

Retentivity

— adjustable Yes

IEC timer

● Number Any (only limited by the main memory)

Retentivity

— can be set Yes

Data areas and their retentivity

Retentive data area (incl. timers, counters, flags), max. 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes

Flag

● Size, max. 16 kbyte

● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte

Data blocks

● Retentivity adjustable Yes

● Retentivity preset No

Local data

● per priority class, max. 64 kbyte; max. 16 KB per block

Address area

Number of IO modules 8 192

I/O address area

● Inputs 32 kbyte; All inputs are in the process image

● Outputs 32 kbyte; All outputs are in the process image

Subprocess images

● Number of subprocess images, max. 32

Hardware configuration

Integrated power supply Yes

Number of distributed IO systems 20

Number of DP masters

● via CM 1

Number of IO Controllers

● via PC interfaces 1

Rack

● Modules per rack, max. 64; CPU 1515SP PC + 64 modules + server module

● Quantity of operable ET 200SP modules, max. 64

● Quantity of operable ET 200AL modules, max. 16

● Number of lines, max. 1

PtP CM

● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots

Time of day

Clock

● Type Hardware clock

● Hardware clock (real-time) Yes; Resolution: 1 s

● Backup time 6 wk; At 40 °C ambient temperature, typically

● Deviation per day, max. 10 s; Typ.: 2 s

Clock synchronization

● supported Yes

● to DP, master Yes

● on Ethernet via NTP Yes

● on Windows clock, device Yes

Interfaces

Number of industrial Ethernet interfaces 2

Number of PROFINET interfaces 1

Number of PROFIBUS interfaces 1

Number of RS 485 interfaces 1; Via CM DP module

Number of USB interfaces 4; 2x USB 2.0, 2x USB 3.0 on front side

Number of SD card slots 1

Video interfaces

● Graphics interface 1x DisplayPort

1. Interface

Interface type PROFINET

automatic detection of transmission rate Yes

Autonegotiation Yes

Autocrossing Yes

Number of connections 88

Interface types

● RJ 45 (Ethernet) Yes; Via BusAdapter BA 2x RJ45

— Transmission rate, max. 100 Mbit/s

— Industrial Ethernet status LED Yes

● Number of ports 2

● integrated switch Yes

● BusAdapter (PROFINET) Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC,

Protocols

● IP protocol Yes; IPv4

● PROFINET IO Controller Yes

● PROFINET IO Device Yes

● SIMATIC communication Yes

● Open IE communication Yes; Optionally also encrypted

● Web server Yes

PROFINET IO Controller

Services

— Isochronous mode Yes

— shortest clock pulse 500 µs

— IRT Yes

— Dynamic Frame Packing (DFP) No

— PROFIenergy Yes

— Prioritized startup Yes; max. 32 PROFINET devices; if you want to use the “Prioritized startup” functionality in STEP 7 for the PROFINET interface of the CPU, the CPU and the device must be separated by means of a switch (e.g. SCALANCE X205)

— Number of connectable IO Devices, max. 128

— Of which IO devices with IRT, max. 64

— of which in line, max. 64

— Number of connectable IO Devices for RT, max. 128

— of which in line, max. 128

— Number of IO Devices that can be simultaneously activated/deactivated, max. 8

— IO Devices changing during operation (partner ports), supported Yes

— Number of IO Devices per tool, max. 8

— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

Update time for IRT

— for send cycle of 500 µs 500 µs to 8 ms

— for send cycle of 1 ms 1 ms to 16 ms

— for send cycle of 2 ms 2 ms to 32 ms

— for send cycle of 4 ms 4 ms to 64 ms

— With IRT and parameterization of “odd” send cycles Update time = set “odd” send clock (any multiple of 125 µs: 625 µs ... 3 875 µs) minimum cycle time start from 500 µs

Update time for RT

— for send cycle of 500 µs 500 µs to 256 ms

— for send cycle of 1 ms 1 ms to 512 ms

— for send cycle of 2 ms 2 ms to 512 ms

— for send cycle of 4 ms 4 ms to 512 ms

Address area

— Inputs, max. 8 kbyte

— Outputs, max. 8 kbyte

PROFINET IO Device

Services

— Isochronous mode No

— shortest clock pulse 500 µs

— IRT Yes

— Dynamic Frame Packing (DFP) No

— PROFIenergy Yes

— Prioritized startup Yes

— Shared device Yes

— Number of IO Controllers with shared device, max. 4

— Asset management record Yes

2. Interface

Interface type Integrated Ethernet interface

automatic detection of transmission rate Yes

Autonegotiation Yes

Autocrossing Yes

Interface types

● RJ 45 (Ethernet) Yes; Integrated

— Transmission rate, max. 1 000 Mbit/s

— Industrial Ethernet status LED No

● Number of ports 1

3. Interface

Interface type PROFIBUS with CM DP

Number of connections 44

Interface types

● RS 485 Yes

Protocols

● PROFIBUS DP master Yes

● PROFIBUS DP device Yes

● SIMATIC communication Yes

PROFIBUS DP master

● max. number of DP devices 125

Services

— Equidistance No

— Isochronous mode No

Address area

— Inputs, max. 8 kbyte

— Outputs, max. 8 kbyte

Interface types

RS 485

● Transmission rate, max. 12 Mbit/s

Protocols

PROFIsafe No

Number of connections

● Number of connections, max. 88

● Number of connections reserved for ES/HMI/web 10

● Number of S7 routing paths 16

Redundancy mode

● PROFINET system redundancy (S2) No

● PROFINET system redundancy (R1) No

Media redundancy

— MRP Yes

— MRP interconnection, supported Yes

— MRPD Yes

— Switchover time on line break, typ. 200 ms

— Number of stations in the ring, max. 50

SIMATIC communication

● PG/OP communication Yes

● S7 routing Yes

● S7 communication, as server Yes

● S7 communication, as client Yes

● User data per job, max. 64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes

Open IE communication

● TCP/IP Yes

— Data length, max. 64 kbyte

● ISO-on-TCP (RFC1006) Yes

— Data length, max. 64 kbyte

● UDP Yes

— Data length, max. 2 048 byte

● SNMP Yes

● DCP Yes

● LLDP Yes

Web server

● HTTP Yes; Via Windows and PROFINET interface

● HTTPS Yes; Via Windows and PROFINET interface

OPC UA

● Runtime license required Yes; “Small” license required

● OPC UA Client Yes; From SW CPU 1505SP V2.6

● OPC UA Server Yes; Data access (read, write, subscribe), runtime license required

— Application authentication Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

— Security policies Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

— User authentication Yes; “anonymous” or by user name & password

Further protocols

● MODBUS Yes; MODBUS TCP

S7 message functions

Number of login stations for message functions, max. 32

Program alarms Yes

Number of configurable program messages, max. 10 000

Number of simultaneously active program alarms 1 000

● Number of program alarms 1 000

● Number of alarms for system diagnostics 200

● Number of alarms for motion technology objects 160

Test commissioning functions

Joint commission (Team Engineering) Yes; Parallel online access possible for up to 8 engineering systems

Status block Yes; up to 8 simultaneously

Single step No

Number of breakpoints 8

Status/control

● Status/control variable Yes

● Variables Inputs, outputs, memory bits, DB, times, counters

● Number of variables, max.

— of which status variables, max. 200

— of which control variables, max. 200

Forcing

● Forcing Yes

● Forcing, variables Inputs, outputs

● Number of variables, max. 200

Diagnostic buffer

● present Yes

● Number of entries, max. 1 000

— of which powerfail-proof 300

Traces

● Number of configurable Traces 4

● Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information

Diagnostics indication LED

● RUN/STOP LED Yes

● ERROR LED Yes

● MAINT LED Yes

Supported technology objects

Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool

● Number of available Motion Control resources for technology objects 2 400

● Required Motion Control resources

— per speed-controlled axis 40; per axis

— per positioning axis 80; per axis

— per synchronous axis 160; per axis

— per external encoder 80; per external encoder

— per output cam 20; per cam

— per cam track 160; per cam track

— per probe 40; per probe

● Positioning axis

— Number of positioning axes at motion control cycle of 4 ms (typical value) 15

— Number of positioning axes at motion control cycle of 8 ms (typical value) 30

Controller

● PID_Compact Yes; Universal PID controller with integrated optimization

● PID_3Step Yes; PID controller with integrated optimization for valves

● PID-Temp Yes; PID controller with integrated optimization for temperature

Counting and measuring

● High-speed counter Yes

Standards, approvals, certificates

CE mark Yes