Description
SIMATIC ET 200SP Open Controller, CPU 1515SP PC2, 8 GB RAM (basic device 6ES7677-2DB40-0AA0), 128 GB CFast with SIMATIC Industrial OS V3.x and S7-1500 Software Controller CPU 1505SP V3x preinstalled; interfaces: 1x slot CFast, 1x slot SD/MMC, 1x connection for ET 200SP BusAdapter PROFINET, 1x 10/100/1000 Mbps Ethernet, 2x USB 3.0; 2x USB 2.0, 1x DisplayPort; documentation on CFast, restore image on SIOS
General information
Product type designation CPU1515SP PC2 - IndOS
Firmware version V31.1
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs
● SysLog Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V20 (FW V31.1) / V18 (FW V30.0) or higher
Installed software
● Visualization No
● Control S7-1500 Software Controller CPU 1505SP
Configuration control
via dataset Yes
Control elements
Mode selector switch 1
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Current consumption (rated value) 1.8 A; Full processor load, incl. ET 200SP modules and using USB
Current consumption (in no-load operation), typ. 0.5 A
Current consumption, max. 2.9 A
I²t 0.426 A²·s; with starting current inrush
Power
Active power input, max. 43 W; incl. ET 200SP modules and using USB
Infeed power to the backplane bus 8.75 W
Power loss
Power loss, typ. 16 W
Processor
Processor type Intel Atom E3940, 1.6 GHz, 4 cores
Storage
Type of memory DDR3L
Main memory 8 GB RAM
CFast memory card Yes; 128 GB flash memory
SIMATIC memory card required No
Work memory
● integrated (for program) 2 Mbyte
● integrated (for data) 7.5 Mbyte
● integrated (for CPU function library of CPU Runtime) 20 Mbyte
Load memory
● integrated (on PC mass storage) 320 Mbyte
Backup
● with UPS Yes; all memory areas declared retentive
● with non-volatile memory Yes
CPU-blocks
Number of elements (total) 8 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements
DB
● Number, max. 7 999; Number range: 1 to 65535
● Size, max. 5 Mbyte
FB
● Number, max. 7 998; Number range: 1 to 65535
● Size, max. 1 024 kbyte
FC
● Number, max. 7 999; Number range: 1 to 65535
● Size, max. 1 024 kbyte
OB
● Size, max. 1 024 kbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 1
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— can be set Yes
S7 timer
● Number 2 048
Retentivity
— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— can be set Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes
Flag
● Size, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable Yes
● Retentivity preset No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 8 192
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
Subprocess images
● Number of subprocess images, max. 32
Hardware configuration
Integrated power supply Yes
Number of distributed IO systems 20
Number of DP masters
● via CM 1
Number of IO Controllers
● via PC interfaces 1
Rack
● Modules per rack, max. 82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
● Quantity of operable ET 200SP modules, max. 64
● Quantity of operable ET 200AL modules, max. 16
● Number of lines, max. 1
PtP CM
● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● Type Hardware clock
● Hardware clock (real-time) Yes; Resolution: 1 s
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Clock synchronization
● supported Yes
● to DP, master Yes; Via CM DP module
● on Ethernet via NTP Yes
● on Windows clock, device Yes
Interfaces
Number of industrial Ethernet interfaces 2
Number of PROFINET interfaces 1
Number of PROFIBUS interfaces 1; Via CM DP module
Number of RS 485 interfaces 1; Via CM DP module
Number of USB interfaces 4; 2x USB 2.0, 2x USB 3.0 on front side
Number of SD card slots 1
Video interfaces
● Graphics interface 1x DisplayPort
1. Interface
Interface type PROFINET
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Number of connections 88
Interface types
● RJ 45 (Ethernet) Yes; Via BusAdapter BA 2x RJ45
— Transmission rate, max. 100 Mbit/s
— Industrial Ethernet status LED Yes
● Number of ports 2
● integrated switch Yes
● BusAdapter (PROFINET) Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy Yes
PROFINET IO Controller
Services
— Isochronous mode Yes
— Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
— shortest clock pulse 500 µs
— IRT Yes
— Dynamic Frame Packing (DFP) No
— PROFIenergy Yes
— Prioritized startup Yes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max. 128
— Of which IO devices with IRT, max. 64
— of which in line, max. 64
— Number of connectable IO Devices for RT, max. 128
— of which in line, max. 128
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8
— IO Devices changing during operation (partner ports), supported Yes
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class 1
Update time for IRT
— for send cycle of 500 µs 500 µs to 8 ms
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
— With IRT and parameterization of “odd” send cycles Update time = set “odd” send clock (any multiple of 125 µs: 625 µs ... 3 875 µs) minimum cycle time start from 500 µs
Update time for RT
— for send cycle of 500 µs 500 µs to 256 ms
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
PROFINET IO Device
Services
— Isochronous mode No
— IRT Yes
— Dynamic Frame Packing (DFP) No
— PROFIenergy Yes; per user program
— Prioritized startup Yes
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— activation/deactivation of I-devices Yes; per user program
— Asset management record Yes; per user program
— PROFINET Security Class SNMP Configuration and DCP Read Only
2. Interface
Interface type Integrated Ethernet interface
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface types
● RJ 45 (Ethernet) Yes; Integrated
— Transmission rate, max. 1 000 Mbit/s
— Industrial Ethernet status LED No
● Number of ports 1
3. Interface
Interface type PROFIBUS with CM DP
Number of connections 44
Interface types
● RS 485 Yes
Protocols
● PROFIBUS DP master Yes
● PROFIBUS DP device Yes
● SIMATIC communication Yes
PROFIBUS DP master
● max. number of DP devices 125
Services
— Equidistance No
— Isochronous mode No
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
Interface types
RS 485
● Transmission rate, max. 12 Mbit/s
Protocols
PROFIsafe No
Number of connections
● Number of connections, max. 88
● Number of connections reserved for ES/HMI/web 10
● Number of S7 routing paths 16
Redundancy mode
● PROFINET system redundancy (S2) No
● PROFINET system redundancy (R1) No
Media redundancy
— Media redundancy Yes; only via BusAdapter
— MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPD Yes; Requirement: IRT
— Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max. 50
SIMATIC communication
● PG/OP communication Yes; encryption with TLS V1.3 pre-selected
● S7 routing Yes
● S7 communication, as server Yes
● S7 communication, as client Yes
● User data per job, max. 64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes
Open IE communication
● TCP/IP Yes
— Data length, max. 64 kbyte
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 64 kbyte
● UDP Yes
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicast Yes; Max. 5 multicast circuits
● DHCP Yes
● DNS Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
● encryption Yes; Optional
Web server
● HTTP Yes; Standard and user pages
● HTTPS Yes; Standard and user pages
● web API
— Number of sessions, max. 50
— number of simultaneous HTTP calls, max. 4
— HTTP request body, max. 131 072 byte
OPC UA
● Runtime license required Yes; “Small” license required
● OPC UA Client Yes; Data access (read, write), method call
— Application authentication Yes
— Security policies Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication Yes; “anonymous” or by user name & password
— Number of connections, max. 10
— Number of nodes of the client interfaces, recommended max. 2 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. 300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. 20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max. 100
— Number of simultaneous calls of the client instructions for session management, per connection, max. 1
— Number of simultaneous calls of the client instructions for data access, per connection, max. 5
— Number of registerable nodes, max. 5 000
— Number of registerable method calls of OPC_UA_MethodCall, max. 100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max. 20
● OPC UA Server Yes; Data access (read, write, subscribe), method call, custom address space
— Application authentication Yes
— Security policies Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication Yes
— GDS support (certificate management) Yes
— Number of sessions, max. 48
— Number of accessible variables, max. 100 000
— Number of registerable nodes, max. 20 000
— Number of subscriptions per session, max. 50
— Sampling interval, min. 100 ms
— Publishing interval, min. 200 ms
— Number of server methods, max. 50
— Number of inputs/outputs per server method, max. 20
— Number of monitored items, recommended max. 2 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max. 10
— Number of nodes for user-defined server interfaces, max. 5 000
● Alarms and Conditions Yes
— Number of program alarms 200
— Number of alarms for system diagnostics 100
Further protocols
● MODBUS Yes; MODBUS TCP
S7 message functions
Number of login stations for message functions, max. 32
Program alarms Yes
Number of configurable program messages, max. 10 000
Number of simultaneously active program alarms 1 000
● Number of program alarms 1 000
● Number of alarms for system diagnostics 200
● Number of alarms for motion technology objects 160
Test commissioning functions
Joint commission (Team Engineering) Yes; Parallel online access possible for up to 10 engineering systems
Status block Yes; up to 8 simultaneously
Single step Yes
Number of breakpoints 8
Profiling No
Status/control
● Status/control variable Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max.
— of which status variables, max. 200; per job
— of which control variables, max. 200; per job
Forcing
● Forcing Yes
● Forcing, variables Peripheral inputs/outputs
● Number of variables, max. 200
Diagnostic buffer
● present Yes
● Number of entries, max. 1 000
— of which powerfail-proof 300
Traces
● Number of configurable Traces 4
● Memory size per trace, max. 512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LED Yes
● ERROR LED Yes
● MAINT LED Yes
Supported technology objects
Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER
● Number of available Motion Control resources for technology objects 2 400
● Required Motion Control resources
— per speed-controlled axis 40
— per positioning axis 80
— per synchronous axis 160
— per external encoder 80
— per output cam 20
— per cam track 160
— per probe 40
● Positioning axis
— Number of positioning axes at motion control cycle of 4 ms (typical value) 30
— Number of positioning axes at motion control cycle of 8 ms (typical value) 30
Controller
● PID_Compact Yes; Universal PID controller with integrated optimization
● PID_3Step Yes; PID controller with integrated optimization for valves