ET 200SP by SEIMENS

ET 200SP, AI 2xI 2-/4-Wire ST, PU 1-6ES7134-6GB00-0BA1

DATA SHEET
In stock

Description

SIMATIC ET 200SP, Analog input module, AI 2xI 2-/4-wire Standard, Pack quantity: 1 unit, suitable for BU type A0, A1, Color code CC05, Module diagnostics, 16 bit

General information

Product type designation AI 2xI 2-/4-wire ST

HW functional status FS22 or higher

Firmware version V2.0.0

● FW update possible Yes

usable BaseUnits BU type A0, A1

Color code for module-specific color-coded label CC05

Product function

● I&M data Yes; I&M0 to I&M3

● Isochronous mode No

● Measuring range scalable No

Engineering with

● STEP 7 TIA Portal configurable/integrated from version V21 HSP0492 / integrated as of V21.1

● STEP 7 configurable/integrated from version V5.7 SP3 HF3 with HSP0348 V2.0 / integrated as of V5.8

● PROFIBUS from GSD version/GSD revision One GSD file each, Revision 3 and 5 and higher

● PROFINET from GSD version/GSD revision GSDML V2.45

Operating mode

● Oversampling No

● MSI No

CiR - Configuration in RUN

Reparameterization possible in RUN Yes

Calibration possible in RUN No

Supply voltage

Rated value (DC) 24 V

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Input current

Current consumption (rated value) 37.5 mA

Current consumption, max. 245 mA

Encoder supply

24 V encoder supply

● 24 V Yes

● Short-circuit protection Yes

● Output current, max. 50 mA; Total current for both channels (two-wire)

Additional 24 V encoder supply

● 24 V Yes

● Short-circuit protection Yes; module-wise

● Output current, max. 200 mA; Total current for both channels (four-wire)

Power loss

Power loss, typ. 0.9 W

Address area

Address space per module

● Address space per module, max. 4 byte; + 1 byte for QI information

Hardware configuration

Automatic encoding Yes

● Mechanical coding element Yes

● Type of mechanical coding element Type A

Selection of BaseUnit for connection variants

● 1-wire connection BU type A0, A1

● 2-wire connection BU type A0, A1

● 4-wire connection BU type A0, A1

Analog inputs

Number of analog inputs 2

● For current measurement 2

permissible input current for current input (destruction limit), max. 50 mA

Cycle time (all channels), min. 500 µs

Input ranges (rated values), currents

● 0 to 20 mA Yes; 15 bit

— Input resistance (0 to 20 mA) 130 Ω; 90 ohms with two wires

● -20 mA to +20 mA Yes; 16 bit incl. sign

— Input resistance (-20 mA to +20 mA) 130 Ω

● 4 mA to 20 mA Yes; 15 bit

— Input resistance (4 mA to 20 mA) 130 Ω; 90 ohms with two wires

Cable length

● shielded, max. 1 000 m

Analog value generation for the inputs

Measurement principle Sigma Delta

Integration and conversion time/resolution per channel

● Resolution with overrange (bit including sign), max. 16 bit

● Integration time, parameterizable Yes

● Interference voltage suppression for interference frequency f1 in Hz 16.6 / 50 / 60 Hz / off

● Conversion time (per channel) 50 ms @ 60 Hz, 60 ms @ 50 Hz, 180 ms @ 16.6 Hz, 500 µs without filter

Smoothing of measured values

● Number of smoothing levels 4

● Parameterizable Yes

● Step: None Yes; 1x conversion time

● Step: low Yes; 4x conversion time

● Step: Medium Yes; 8x conversion time

● Step: High Yes; 16x conversion time

Encoder

Connection of signal encoders

● for current measurement as 2-wire transducer Yes

— Burden of 2-wire transmitter, max. 650 Ω

● for current measurement as 4-wire transducer Yes

Errors/accuracies

Linearity error (relative to input range), (+/-) 0.01 %

Temperature error (relative to input range), (+/-) 0.005 %/K

Crosstalk between the inputs, min. -50 dB

Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.05 %

Operational error limit in overall temperature range

● Current, relative to input range, (+/-) 0.5 %

Basic error limit (operational limit at 25 °C)

● Current, relative to input range, (+/-) 0.3 %

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

● Series mode interference (peak value of interference < rated value of input range), min. 70 dB

● Common mode voltage, max. 10 V

● Common mode interference, min. 90 dB

Interrupts/diagnostics/status information

Diagnostics function Yes

Alarms

● Diagnostic alarm Yes

● Limit value alarm No

Diagnoses

● Monitoring the supply voltage Yes

● Wire break Yes; at 4 to 20 mA

● Short-circuit Yes; Short-circuit of the encoder supply

● Group error Yes

● Overflow/Underflow Yes

Diagnostics indication LED

● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED

● Channel status display Yes; green LED

● for channel diagnostics No

● for module diagnostics Yes; green/red DIAG LED

Potential separation

Potential separation channels

● between the channels No

● between the channels and backplane bus Yes

● between the channels and the power supply of the electronics Yes

Permissible potential difference

between the inputs (UCM) 10 Vpp

Isolation

Isolation tested with 707 V DC (type test)

Standards, approvals, certificates

Ecological footprint

● environmental product declaration Yes

Global warming potential

— global warming potential, (total) [CO2 eq] 9.32 kg

— global warming potential, (during production) [CO2 eq] 4.97 kg

— global warming potential, (during operation) [CO2 eq] 4.79 kg

— global warming potential, (after end of life cycle) [CO2 eq] -0.449 kg

Security

signed firmware update Yes; firmware V2.0.0 or higher

Ambient conditions