Description
SIMATIC ET 200SP, digital input module, DI 8x 24 V AC..48 V UC Basic, packing quantity: 1 unit, suitable for BU type U0, color code CC20, module diagnostics
General information
Product type designation DI 8x24VAC/48VUC BA
HW functional status From FS02
Firmware version V0.0
● FW update possible No
usable BaseUnits BU type U0
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode No
● suitable for operation on PROFINET R1 IMs Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V15
● STEP 7 configurable/integrated from version V5.6
● PROFIBUS from GSD version/GSD revision One GSD file each, Revision 3 and 5 and higher
● PROFINET from GSD version/GSD revision GSDML V2.3
Operating mode
● DI Yes
● Counter No
● Oversampling No
● MSI No
Supply voltage
Rated value (DC) 48 V
permissible range, lower limit (DC) 40.8 V
permissible range, upper limit (DC) 57.6 V
Rated value (AC) 48 V; 24 V/48 V; 50 Hz/60 Hz
permissible range, lower limit (AC) 40.8 V
permissible range, upper limit (AC) 52.8 V
Reverse polarity protection Yes
Input current
Current consumption, max. 70 mA; without sensor supply
Encoder supply
Number of outputs 8
Short-circuit protection Yes; Per module, 5x 20 mm fuse, 2 A/250 V, quick-response, replaceable
Output current
● up to 60 °C, max. 1 A
24 V encoder supply
● 24 V No
Power loss
Power loss, typ. 1.5 W
Address area
Address space per module
● Address space per module, max. 1 byte
Hardware configuration
Automatic encoding
● Mechanical coding element Yes
● Type of mechanical coding element type C
Selection of BaseUnit for connection variants
● 1-wire connection BU type U0
● 2-wire connection BU type U0
● 3-wire connection BU type U0 + Potential distributor module
● 4-wire connection BU type U0 + Potential distributor module
Digital inputs
Number of digital inputs 8
Sourcing/sinking input P-reading
Input characteristic curve in accordance with IEC 61131, type 1 Yes
Input characteristic curve in accordance with IEC 61131, type 2 No
Input characteristic curve in accordance with IEC 61131, type 3 No
Pulse extension No
Input voltage
● for signal “0” AC/DC < 10 V
● for signal “1” AC > 14 V, DC > 34 V
Input current
● for signal “1”, typ. 3.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— Parameterizable No
— at “0” to “1”, max. 15 ms
— at “1” to “0”, max. 20 ms
Cable length
● shielded, max. 1 000 m
● unshielded, max. 600 m
Encoder
Connectable encoders
● 2-wire sensor Yes
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
Diagnoses
● Diagnostic information readable Yes
● Monitoring the supply voltage Yes
● Monitoring of encoder power supply Yes
● Group error Yes
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● Channel status display Yes; green LED
● for channel diagnostics No
● for module diagnostics Yes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channels No
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics No
Isolation
Isolation tested with 1 200 V DC between supply voltage and backplane bus
Standards, approvals, certificates
Suitable for safety functions No
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 15.9 kg
— global warming potential, (during production) [CO2 eq] 3.69 kg
— global warming potential, (during operation) [CO2 eq] 12.7 kg
— global warming potential, (after end of life cycle) [CO2 eq] -0.495 kg
Specifications
| - | - |
|---|---|
| - | - |