S7-1500, AI 8 X U/R/RTD/TC HF-6ES7531-7PF00-0AB0

INR 1
Learn more
In stock

Description

SIMATIC S7-1500 analog input module AI 8xU/R/RTD/TC HF, 16 bit resolution, up to 21 bit Resolution at RT and TC, accuracy 0.1%, 8 channels in groups of 1; common mode voltage: 30 V AC/60 V DC, Diagnostics; Hardware interrupts Scalable temperature measuring range, thermocouple type C, Calibrate in RUN; Delivery including infeed element, shield bracket and shield terminal: Front connector (screw terminals or push-in) to be ordered separately

General information

Product type designation AI 8xU/R/RTD/TC HF

HW functional status from FS01

Firmware version V1.1.0

● FW update possible Yes

Product function

● I&M data Yes; I&M0 to I&M3

● Isochronous mode No

● Prioritized startup Yes

● Measuring range scalable Yes

● Scalable measured values No

● Adjustment of measuring range No

Engineering with

● STEP 7 TIA Portal configurable/integrated from version V14 / -

● STEP 7 configurable/integrated from version V5.5 SP3 / -

● PROFIBUS from GSD version/GSD revision V1.0 / V5.1

● PROFINET from GSD version/GSD revision V2.3 / -

Operating mode

● Oversampling No

● MSI Yes

CiR - Configuration in RUN

Reparameterization possible in RUN Yes

Calibration possible in RUN Yes

Supply voltage

Rated value (DC) 24 V

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Input current

Current consumption, max. 55 mA; with 19.2 V supply

Power

Power consumption from the backplane bus 0.85 W

Power loss

Power loss, typ. 1.9 W

Address area

Address space per module

● Inputs 18 byte

● Outputs 0 byte

Analog inputs

Number of analog inputs 8; Plus one additional RTD (reference) channel

● For voltage measurement 8; Plus one additional RTD (reference) channel

● For resistance/resistance thermometer measurement 8; Plus one additional RTD (reference) channel

● For thermocouple measurement 8; Plus one additional RTD (reference) channel

permissible input voltage for voltage input (destruction limit), max. 20 V

Constant measurement current for resistance-type transmitter, typ. 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100, Pt200 climate: 1 mA; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt200 standard, Pt500, Pt1000, PTC: 0.25 mA

Technical unit for temperature measurement adjustable Yes; °C/°F/K

Analog input with oversampling No

Standardization of measured values Yes; See manual for details

Input ranges (rated values), voltages

● 0 to +5 V No

● 0 to +10 V No

● 1 V to 5 V No

● -1 V to +1 V Yes

— Input resistance (-1 V to +1 V) 10 MΩ

● -10 V to +10 V No

● -2.5 V to +2.5 V No

● -25 mV to +25 mV Yes

— Input resistance (-25 mV to +25 mV) 10 MΩ

● -250 mV to +250 mV Yes

— Input resistance (-250 mV to +250 mV) 10 MΩ

● -5 V to +5 V No

● -50 mV to +50 mV Yes

— Input resistance (-50 mV to +50 mV) 10 MΩ

● -500 mV to +500 mV Yes

— Input resistance (-500 mV to +500 mV) 10 MΩ

● -80 mV to +80 mV Yes

— Input resistance (-80 mV to +80 mV) 10 MΩ

Input ranges (rated values), currents

● 0 to 20 mA No

● -20 mA to +20 mA No

● 4 mA to 20 mA No

Input ranges (rated values), thermocouples

● type B Yes

— Input resistance (Type B) 10 MΩ

● type C Yes

— Input resistance (Type C) 10 MΩ

● Type E Yes

— Input resistance (Type E) 10 MΩ

● Type J Yes

— Input resistance (type J) 10 MΩ

● Type K Yes

— Input resistance (Type K) 10 MΩ

● Type L No

● Type N Yes

— Input resistance (Type N) 10 MΩ

● Type R Yes

— Input resistance (Type R) 10 MΩ

● Type S Yes

— Input resistance (Type S) 10 MΩ

● Type T Yes

— Input resistance (Type T) 10 MΩ

● Type TXK/TXK(L) to GOST Yes

— Input resistance (Type TXK/TXK(L) to GOST) 10 MΩ

Input ranges (rated values), resistance thermometer

● Cu 10 Yes; Standard/climate

— Input resistance (Cu 10) 10 MΩ

● Cu 10 according to GOST Yes; Standard/climate

— Input resistance (Cu 10 according to GOST) 10 MΩ

● Cu 50 Yes; Standard/climate

— Input resistance (Cu 50) 10 MΩ

● Cu 50 according to GOST Yes; Standard/climate

— Input resistance (Cu 50 according to GOST) 10 MΩ

● Cu 100 Yes; Standard/climate

— Input resistance (Cu 100) 10 MΩ

● Cu 100 according to GOST Yes; Standard/climate

— Input resistance (Cu 100 according to GOST) 10 MΩ

● Ni 10 Yes; Standard/climate

— Input resistance (Ni 10) 10 MΩ

● Ni 10 according to GOST Yes; Standard/climate

— Input resistance (Ni 10 according to GOST) 10 MΩ

● Ni 100 Yes; Standard/climate

— Input resistance (Ni 100) 10 MΩ

● Ni 100 according to GOST Yes; Standard/climate

— Input resistance (Ni 100 according to GOST) 10 MΩ

● Ni 1000 Yes; Standard/climate

— Input resistance (Ni 1000) 10 MΩ

● Ni 1000 according to GOST Yes; Standard/climate

— Input resistance (Ni 1000 according to GOST) 10 MΩ

● LG-Ni 1000 Yes; Standard/climate

— Input resistance (LG-Ni 1000) 10 MΩ

● Ni 120 Yes; Standard/climate

— Input resistance (Ni 120) 10 MΩ

● Ni 120 according to GOST Yes; Standard/climate

— Input resistance (Ni 120 according to GOST) 10 MΩ

● Ni 200 Yes; Standard/climate

— Input resistance (Ni 200) 10 MΩ

● Ni 200 according to GOST Yes; Standard/climate

— Input resistance (Ni 200 according to GOST) 10 MΩ

● Ni 500 Yes; Standard/climate

— Input resistance (Ni 500) 10 MΩ

● Ni 500 according to GOST Yes; Standard/climate

— Input resistance (Ni 500 according to GOST) 10 MΩ

● Pt 10 Yes; Standard/climate

— Input resistance (Pt 10) 10 MΩ

● Pt 10 according to GOST Yes; Standard/climate

— Input resistance (Pt 10 according to GOST) 10 MΩ

● Pt 50 Yes; Standard/climate

— Input resistance (Pt 50) 10 MΩ

● Pt 50 according to GOST Yes; Standard/climate

— Input resistance (Pt 50 according to GOST) 10 MΩ

● Pt 100 Yes; Standard/climate

— Input resistance (Pt 100) 10 MΩ

● Pt 100 according to GOST Yes; Standard/climate

— Input resistance (Pt 100 according to GOST) 10 MΩ

● Pt 1000 Yes; Standard/climate

— Input resistance (Pt 1000) 10 MΩ

● Pt 1000 according to GOST Yes; Standard/climate

— Input resistance (Pt 1000 according to GOST) 10 MΩ

● Pt 200 Yes; Standard/climate

— Input resistance (Pt 200) 10 MΩ

● Pt 200 according to GOST Yes; Standard/climate

— Input resistance (Pt 200 according to GOST) 10 MΩ

● Pt 500 Yes; Standard/climate

— Input resistance (Pt 500) 10 MΩ

● Pt 500 according to GOST Yes; Standard/climate

— Input resistance (Pt 500 according to GOST) 10 MΩ

Input ranges (rated values), resistors

● 0 to 150 ohms Yes

— Input resistance (0 to 150 ohms) 10 MΩ

● 0 to 300 ohms Yes

— Input resistance (0 to 300 ohms) 10 MΩ

● 0 to 600 ohms Yes

— Input resistance (0 to 600 ohms) 10 MΩ

● 0 to 3000 ohms No

● 0 to 6000 ohms Yes

— Input resistance (0 to 6000 ohms) 10 MΩ

● PTC Yes

— Input resistance (PTC) 10 MΩ

Thermocouple (TC)

Temperature compensation

— Parameterizable Yes

— internal temperature compensation Yes

— external temperature compensation via RTD Yes

— Compensation for 0 °C reference point temperature Yes; fixed value can be set

— Reference channel of the module Yes; 9th channel that can be used as a genuine 9th RTD channel regardless of the parameterization of the other channels, or that can be used for compensation in the case of TC measurement

Cable length

● shielded, max. 800 m; at U; 200 m at R/RTD/TC

Analog value generation for the inputs

Measurement principle integrating

Integration and conversion time/resolution per channel

● Resolution with overrange (bit including sign), max. 21 bit; For measuring mode RTC and TC when using the function “Scalable temperature measuring range” (32 bit REAL format); 16 bit for measuring mode R and U; 16 bit for all measuring modes when using the S7 format (16 bit INTEGER)

● Integration time, parameterizable Yes

● Integration time (ms) Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms

● Basic conversion time, including integration time (ms) Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms

— additional conversion time for wire-break monitoring Thermocouples, 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100: 4 ms; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt200, Pt500, Pt1000: 13 ms

● Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 Hz

● Basic execution time of the module (all channels released) Corresponds to the channel with the highest basic conversion time

Smoothing of measured values

● Number of smoothing levels 4

● Parameterizable Yes

● Step: None Yes

● Step: low Yes

● Step: Medium Yes

● Step: High Yes

Encoder

Connection of signal encoders

● for voltage measurement Yes

● for current measurement as 2-wire transducer No

● for current measurement as 4-wire transducer No

● for resistance measurement with two-wire connection Yes

● for resistance measurement with three-wire connection Yes; All measuring ranges except PTC; internal compensation of the cable resistances

● for resistance measurement with four-wire connection Yes; All measuring ranges except PTC

Errors/accuracies

Linearity error (relative to input range), (+/-) 0.02 %

Temperature error (relative to input range), (+/-) 0.005 %/K

Crosstalk between the inputs, max. -80 dB

Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.02 %

Temperature error of internal compensation ±1,5 °C

Operational error limit in overall temperature range

● Voltage, relative to input range, (+/-) 0.1 %

● Resistance, relative to input range, (+/-) 0.1 %

● Resistance thermometer, relative to input range, (+/-) Cuxxx Standard: ±0.5 K, Cuxxx Klima: ±0.5 K, Ptxxx Standard: ±1 K, Ptxxx Klima: ±0.5 K, Nixxx Standard: ±0.5 K, Nixxx Klima: ±0.3 K

● Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±2 K, Type E: > -200 °C ±1 K, Type J: > -210 °C ±1 K, Type K: > -200 °C ±2 K, Type N: > -200 °C ±2 K, Type R: > 0 °C ±2 K, Type S: > 0 °C ±2 K, Type T: > -200 °C ±1 K, Type C: ±4 K, Type TXK/TXK(L): ±1 K

Basic error limit (operational limit at 25 °C)

● Voltage, relative to input range, (+/-) 0.05 %

● Resistance, relative to input range, (+/-) 0.05 %

● Resistance thermometer, relative to input range, (+/-) Cuxxx Standard: ±0.3 K, Cuxxx Klima: ±0.2 K, Ptxxx Standard: ±0.5 K, Ptxxx Klima: ±0.2 K, Nixxx Standard: ±0.3 K, Nixxx Klima: ±0.15 K

● Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±1 K, Type E: > -200 °C ±0.5 K, Type J: > -210 °C ±0.5 K, Type K: > -200 °C ±1 K, Type N: > -200 °C ±1 K, Type R: > 0 °C ±1 K, Type S: > 0 °C ±1 K, Type T: > -200 °C ±0.5 K, Type C: ±2 K, Type TXK/TXK(L): ±0.5 K

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

● Series mode interference (peak value of interference < rated value of input range), min. 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode

● Common mode voltage, max. 60 V DC/30 V AC

● Common mode interference, min. 80 dB

Interrupts/diagnostics/status information

Diagnostics function Yes

Alarms

● Diagnostic alarm Yes

● Limit value alarm Yes; two upper and two lower limit values in each case

Diagnoses

● Monitoring the supply voltage Yes

● Wire break Yes; Only with TC, R, RTD

● short-circuit No

● Group error No

● Overflow/Underflow Yes

Diagnostics indication LED

● RUN LED Yes; green LED

● ERROR LED Yes; red LED

● MAINT LED No

● Monitoring of the supply voltage (PWR-LED) Yes; green LED

● Channel status display Yes; green LED

● for channel diagnostics Yes; red LED

● for module diagnostics Yes; red LED

Potential separation

Potential separation channels

● between the channels Yes

● between the channels, in groups of 1

● between the channels and backplane bus Yes

● between the channels and the power supply of the electronics Yes

Permissible potential difference

between different circuits 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels

Isolation

Isolation tested with 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus

Standards, approvals, certificates

Siemens Eco Profile (SEP) Siemens EcoTech

Suitable for applications according to AMS 2750 Yes; Declaration of Conformity, see online support entry 109757262

Suitable for applications according to CQI-9 Yes; Based on AMS 2750 E

Ecological footprint

● environmental product declaration Yes

Global warming potential

— global warming potential, (total) [CO2 eq] 38.6 kg

— global warming potential, (during production) [CO2 eq] 14.4 kg

— global warming potential, (during operation) [CO2 eq] 24.6 kg

— global warming potential, (after end of life cycle) [CO2 eq]