S7-1500 by siemens

S7-1500, AQ 8xHART HF-6ES7532-8TF00-0AB0

INR 1
Learn more
In stock

Description

SIMATIC S7-1500, analog output module AQ 8xHART HF, 16-bit resolution, accuracy 0.2%, 8 channels in groups of 8 diagnostics, substitute values, delivery including infeed element, shielding bracket and shield terminal; front connector (screw terminals or push-in) to be ordered separately

General information

Product type designation AQ 8xHART HF

HW functional status from FS01

Firmware version V1.0.0

● FW update possible Yes

Product function

● I&M data Yes; I&M0 to I&M3

● Isochronous mode No

● Prioritized startup No

● Output range scalable No

Engineering with

● STEP 7 TIA Portal configurable/integrated from version V18 and V19 with HSP0423

● STEP 7 configurable/integrated from version V5.5 SP3 / -

● PROFIBUS from GSD version/GSD revision V1.0 / V5.1

● PROFINET from GSD version/GSD revision V 2.43 / -

Operating mode

● Oversampling No

● MSO Yes

CiR - Configuration in RUN

Reparameterization possible in RUN Yes

Calibration possible in RUN Yes

Supply voltage

Rated value (DC) 24 V

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Input current

Current consumption (rated value) 280 mA; 8x 20 mA with 750 ohm load resistance

Current consumption, max. 370 mA

Power

Power consumption from the backplane bus 0.6 W

Power loss

Power loss, typ. 4.8 W; 8x 20 mA with 750 ohm load resistance

Analog outputs

Number of analog outputs 8

Voltage output, short-circuit protection Yes

Current output, no-load voltage, max. 30 V

Cycle time (all channels), min. 5 ms; independent of number of activated channels

Analog output with oversampling No

Output ranges, current

● 0 to 10 mA No

● 0 to 20 mA Yes

● -20 mA to +20 mA No

● 4 mA to 20 mA Yes

Connection of actuators

● for voltage output two-wire connection No

● for voltage output four-wire connection No

● for current output two-wire connection Yes

Load impedance (in rated range of output)

● with current outputs, max. 750 Ω

● with current outputs, inductive load, max. 10 mH

Cable length

● shielded, max. 800 m

Analog value generation for the outputs

Integration and conversion time/resolution per channel

● Resolution with overrange (bit including sign), max. 16 bit

Settling time

● for resistive load 3 ms; see additional description in the manual

● for inductive load 3 ms; see additional description in the manual

Errors/accuracies

Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) 0.02 %

Linearity error (relative to output range), (+/-) 0.02 %

Temperature error (relative to output range), (+/-) 0.002 %/K

Crosstalk between the outputs, max. -100 dB

Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) 0.02 %

note regarding accuracy at temperatures below 0 °C, the figures for operating error and temperature error are doubled

Operational error limit in overall temperature range

● Current, relative to output range, (+/-) 0.2 %

Basic error limit (operational limit at 25 °C)

● Current, relative to output range, (+/-) 0.1 %

Interrupts/diagnostics/status information

Diagnostics function Yes

Substitute values connectable Yes

Alarms

● Diagnostic alarm Yes

Diagnoses

● Monitoring the supply voltage Yes

● Wire break Yes

● Short-circuit Yes

● Overflow/Underflow Yes

Diagnostics indication LED

● RUN LED Yes; green LED

● ERROR LED Yes; red LED

● Monitoring of the supply voltage (PWR-LED) Yes; green LED

● Channel status display Yes; green LED

● for channel diagnostics Yes; red LED

● for module diagnostics Yes; red LED

Potential separation

Potential separation channels

● between the channels No

● between the channels, in groups of 8

● between the channels and backplane bus Yes

● Between the channels and load voltage L+ Yes

Permissible potential difference

between different circuits 60 V DC/30 V AC

Isolation

Isolation tested with 707 V DC (type test)

Standards, approvals, certificates

Siemens Eco Profile (SEP) Siemens EcoTech

Suitable for safety-related tripping of standard modules No

Ecological footprint

● environmental product declaration Yes

Global warming potential

— global warming potential, (total) [CO2 eq] 37.6 kg

— global warming potential, (during production) [CO2 eq] 11.1 kg

— global warming potential, (during operation) [CO2 eq] 26.8 kg

— global warming potential, (after end of life cycle) [CO2 eq] -0.364 kg

Security

signed firmware update Yes

safely removing data No

data integrity No

Ambient conditions

Ambient temperature during operation

● horizontal installation, min. -30 °C

● horizontal installation, max. 60 °C

● vertical installation, min. -30 °C

● vertical installation, max. 40 °C

Altitude during operation relating to sea level

● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual

Absolute humidity

● dew point, min. -60 °C; suitable for dry room applications

Dimensions

Width 35 mm

Height 147 mm

Depth 129 mm

Weights

Weight, approx. 300 g

Other

Note: please order front connectors (screw-in/push-in) separately