S7-1500, AQ 8xU/I HS-6ES7532-5HF00-0AB0

INR 1
Learn more
In stock

Description

SIMATIC S7-1500, analog output module AQ8xU/I HS, 16-bit resolution accuracy 0.3%, 8 channels in groups of 8, diagnostics; substitute value 8 channels in 0.125 ms oversampling; the module supports the safety-oriented shutdown of load groups up to SIL2 according to EN IEC 62061:2021 and Category 3 / PL d according to EN ISO 13849-1:2015. delivery including infeed element, shielding bracket and shield terminal: front connector (screw terminals or push-in) to be ordered separately

General information

Product type designation AQ 8xU/I HS

HW functional status from FS01

Firmware version V2.1.0

● FW update possible Yes

Product function

● I&M data Yes; I&M0 to I&M3

● Isochronous mode Yes

● Prioritized startup No

● Output range scalable No

Engineering with

● STEP 7 TIA Portal configurable/integrated from version V14 / -

● STEP 7 configurable/integrated from version V5.5 SP3 / -

● PROFIBUS from GSD version/GSD revision V1.0 / V5.1

● PROFINET from GSD version/GSD revision V2.3 / -

Operating mode

● Oversampling Yes

● MSO Yes

CiR - Configuration in RUN

Reparameterization possible in RUN Yes

Calibration possible in RUN Yes

Supply voltage

Rated value (DC) 24 V

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Input current

Current consumption, max. 320 mA; with 19.2 V supply

Power

Power consumption from the backplane bus 1.15 W

Power loss

Power loss, typ. 7 W

Analog outputs

Number of analog outputs 8

Voltage output, short-circuit protection Yes

Voltage output, short-circuit current, max. 45 mA

Current output, no-load voltage, max. 20 V

Cycle time (all channels), min. 125 µs; independent of number of activated channels

Analog output with oversampling Yes

● Values per cycle, max. 16

● Resolution, min. 125 µs

Output ranges, voltage

● 0 to 10 V Yes

● 1 V to 5 V Yes

● -5 V to +5 V No

● -10 V to +10 V Yes

Output ranges, current

● 0 to 20 mA Yes

● -20 mA to +20 mA Yes

● 4 mA to 20 mA Yes

Connection of actuators

● for voltage output two-wire connection Yes

● for voltage output four-wire connection Yes

● for current output two-wire connection Yes

Load impedance (in rated range of output)

● with voltage outputs, min. 1 kΩ

● with voltage outputs, capacitive load, max. 100 nF

● with current outputs, max. 500 Ω

● with current outputs, inductive load, max. 1 mH

Cable length

● shielded, max. 200 m

Analog value generation for the outputs

Integration and conversion time/resolution per channel

● Resolution with overrange (bit including sign), max. 16 bit

● Conversion time (per channel) 50 µs; independent of number of activated channels

Settling time

● for resistive load 30 µs; see additional description in the manual

● for capacitive load 100 µs; see additional description in the manual

● for inductive load 100 µs; see additional description in the manual

Errors/accuracies

Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) 0.02 %

Linearity error (relative to output range), (+/-) 0.15 %

Temperature error (relative to output range), (+/-) 0.002 %/K

Crosstalk between the outputs, max. -100 dB

Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) 0.05 %

note regarding accuracy at temperatures below 0 °C, the figures for operating error and temperature error are doubled

Operational error limit in overall temperature range

● Voltage, relative to output range, (+/-) 0.3 %

● Current, relative to output range, (+/-) 0.3 %

Basic error limit (operational limit at 25 °C)

● Voltage, relative to output range, (+/-) 0.2 %

● Current, relative to output range, (+/-) 0.2 %

Isochronous mode

Execution and activation time (TCO), min. 100 µs

Bus cycle time (TDP), min. 250 µs

Interrupts/diagnostics/status information

Diagnostics function Yes

Substitute values connectable Yes

Alarms

● Diagnostic alarm Yes

Diagnoses

● Monitoring the supply voltage Yes

● Wire break Yes; Only for output type “current”

● short-circuit Yes; Only for output type “voltage”

● Overflow/Underflow Yes

Diagnostics indication LED

● RUN LED Yes; green LED

● ERROR LED Yes; red LED

● Monitoring of the supply voltage (PWR-LED) Yes; green LED

● Channel status display Yes; green LED

● for channel diagnostics Yes; red LED

● for module diagnostics Yes; red LED

Potential separation

Potential separation channels

● between the channels No

● between the channels, in groups of 8

● between the channels and backplane bus Yes

● Between the channels and load voltage L+ Yes

Permissible potential difference

between S- and MANA (UCM) 8 V DC

Isolation

Isolation tested with 707 V DC (type test)

Standards, approvals, certificates

Siemens Eco Profile (SEP) Siemens EcoTech

Suitable for safety-related tripping of standard modules Yes; from FS04

Ecological footprint

● environmental product declaration Yes

Global warming potential

— global warming potential, (total) [CO2 eq] 37.6 kg

— global warming potential, (during production) [CO2 eq] 11.1 kg

— global warming potential, (during operation) [CO2 eq] 26.8 kg

— global warming potential, (after end of life cycle) [CO2 eq]