DATA SHEET
In stock

Description

SIMATIC S7-1500, digital input module DI 16x24 V DC AUX; 16 channels in groups of 8; for 24 V encoder; sensor supply 24 V DC; input type 2 (IEC 61131); input delay parameterizable 0.05..20 ms; isochronous mode up to 250 µs; integrated counting function up to 20 kHz; pulse stretching; chatter monitoring; signal inversion diagnostics; hardware interrupts: front connector (screw terminals or push-in) and, if applicable, order shield set separately

General information

Product type designation DI 16x24 V DC HS

HW functional status from FS01

Firmware version V1.0.0

● FW update possible Yes

Product function

● I&M data Yes; I&M0 to I&M3

● Isochronous mode Yes

● Prioritized startup Yes

Engineering with

● STEP 7 TIA Portal configurable/integrated from version STEP 7 V17 or higher

● STEP 7 configurable/integrated from version V5.5 SP3 / -

● PROFIBUS from GSD version/GSD revision V1.0 / V5.1

● PROFINET from GSD version/GSD revision V2.3 / -

Operating mode

● DI Yes

● Counter Yes

● Oversampling Yes

● MSI Yes

Supply voltage

Rated value (DC) 24 V

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Input current

Current consumption, max. 550 mA

Encoder supply

Number of outputs 16; 2x 24 V DC

Short-circuit protection Yes

24 V encoder supply

● 24 V Yes

● Short-circuit protection Yes; Per group, electronic

● Output current, max. 150 mA; per group

● Output current per module, max. 300 mA

Power

Power consumption from the backplane bus 0.6 W

Power loss

Power loss, typ. 7 W

Address area

Address space per module

● Inputs 2 byte

● Outputs 0 byte

Digital inputs

Number of digital inputs 16

Digital inputs, parameterizable Yes

Sourcing/sinking input P-reading

Input characteristic curve in accordance with IEC 61131, type 2 Yes

Pulse extension Yes; 0.05 s, 0.1 s, 0.2 s, 0.5 s, 1 s, 2 s

Edge evaluation Yes; Positive edge, negative edge

Signal change flutter Yes; 2 to 32 signal changes

Flutter observation window Yes; 0.5 s, 1 s to 100 s in 1-s steps

Number of simultaneously controllable inputs

● Number of simultaneously controllable inputs 16; see additional description in the manual

Digital input functions, parameterizable

● Gate start/stop Yes; software/hardware gate

● Freely usable digital input Yes

● Counter

— Number, max. 4; 4 totalizers max. 10 kHz or 2 totalizers max. 20 kHz + 2 totalizers max. 10 kHz

— Counting frequency, max. 20 kHz

— Counting width 32 bit

— Counting direction up/down Yes

● Digital input with oversampling Yes

— Number, max. 16

— Values per cycle, max. 16

— Resolution, min. 15.625 µs

Input voltage

● Rated value (DC) 24 V

● for signal “0” -30 to +5 V

● for signal “1” +11 to +30V

Input current

● for signal “1”, typ. 9 mA

Input delay (for rated value of input voltage)

for standard inputs

— parameterizable Yes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms

— at “0” to “1”, min. 0.05 ms

— at “0” to “1”, max. 20 ms

— at “1” to “0”, min. 0.05 ms

— at “1” to “0”, max. 20 ms

for interrupt inputs

— parameterizable Yes

for technological functions

— parameterizable Yes

Cable length

● shielded, max. 1 000 m; 600 m for technological functions; depending on input frequency, encoder and cable quality; max. 50 m at 20 kHz

● unshielded, max. 600 m; for technological functions: No

Encoder

Connectable encoders

● 2-wire sensor Yes

— permissible quiescent current (2-wire sensor), max. 2 mA

Isochronous mode

Filtering and processing time (TCI), min. 60 µs; At 50 μs filter time

Bus cycle time (TDP), min. 250 µs

Interrupts/diagnostics/status information

Diagnostics function Yes

Alarms

● Diagnostic alarm Yes

● Hardware interrupt Yes

Diagnoses

● Monitoring the supply voltage Yes

● Monitoring of encoder power supply Yes; short-circuit

● Wire break Yes; to I < 350 µA

● Short-circuit No

Diagnostics indication LED

● RUN LED Yes; green LED

● ERROR LED Yes; red LED

● Monitoring of the supply voltage (PWR-LED) Yes; green LED

● Channel status display Yes; green LED

● for channel diagnostics Yes; red LED

● for module diagnostics Yes; red LED

Potential separation

Potential separation channels

● between the channels No

● between the channels, in groups of 8

● between the channels and backplane bus Yes

● Between the channels and load voltage L+ Yes

● between the channels and the power supply of the electronics No

Isolation

Isolation tested with 707 V DC (type test)

Standards, approvals, certificates

Siemens Eco Profile (SEP) Siemens EcoTech

Suitable for safety functions No

Ecological footprint

● environmental product declaration Yes

Global warming potential

— global warming potential, (total) [CO2 eq] 18.9 kg

— global warming potential, (during production) [CO2 eq] 12.1 kg

— global warming potential, (during operation) [CO2 eq] 7.66 kg

— global warming potential, (after end of life cycle) [CO2 eq]