Description
SIMATIC S7-1500, digital output module, DQ 8x24 V DC/5 A AUX, width 35 mm, 8 channels in groups of 4, 5 A / channel, 8 A / group, per group, two channels can be parallel-switched (2 x 8 A), 8 channels with pulse width modulation (PWM; max 12.5 kHz), front connector (screw terminal or push-in) to be ordered separately
General information
Product type designation DQ 8x24VDC/5A HS
HW functional status from FS01
Firmware version from V1.0.0
● FW update possible Yes
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes
● Prioritized startup Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V18 with HSP 0434 / V20
● STEP 7 configurable/integrated from version STEP 7 V5.7 or higher SP1 or higher
● PROFIBUS from GSD version/GSD revision revision 3 / version 5.1
● PROFINET from GSD version/GSD revision V 2.43 / -
Operating mode
● DQ Yes
● DQ with energy-saving function Yes; Valve control
● PWM Yes; max. 12.5 kHz
● Cam control (switching at comparison values) No
● Oversampling Yes
● MSO Yes
● Integrated operating cycle counter Yes
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes; through internal protection with 10 A per group
Input current
Current consumption, max. 40 mA; 20 mA per group, no output is activated.
Output voltage
Rated value (DC) 24 V
Power
Power consumption from the backplane bus 0.55 W
Power loss
Power loss, typ. 2.4 W
Address area
Address space per module
● Inputs 0 byte
● Outputs 1 byte
Digital outputs
Type of digital output Transistor
Number of digital outputs 8
Current-sinking No
Current-sourcing Yes; Push-pull output
Digital outputs, parameterizable Yes
Short-circuit protection Yes
● Response threshold, typ. 10 A; 4 us response time
Open-circuit detection No
Overload protection Thermal overload protection
Limitation of inductive shutdown voltage to M (-1 V)
Controlling a digital input Yes
Digital output functions, parameterizable
● Switching tripped by comparison values No
● Freely usable digital output Yes
● PWM output Yes
— Number, max. 8
— Cycle duration, parameterizable Yes; 0.08 ... 100 ms
— ON period, min. 0 %
— ON period, max. 100 %
— Resolution of the duty cycle 0.1 %
— Minimum pulse duration 30 µs
● Digital output with oversampling Yes
— Number, max. 8
— Values per cycle, max. 16
Switching capacity of the outputs
● with resistive load, max. 5 A
● with inductive load, max. 5 A
● on lamp load, max. 10 W
Load resistance range
● lower limit 4.8 Ω
● upper limit 4 kΩ
Output voltage
● for signal “1”, min. L+ (-0.8 V)
Output current
● for signal “1” rated value 5 A
● for signal “1” permissible range, max. 6 A; note derating data in the manual
● for signal “0” residual current, max. 0.5 mA
Output delay with resistive load
● “0” to “1”, typ. 3 µs
● “1” to “0”, typ. 3 µs
Parallel switching of two outputs
● for logic links No
● for uprating Yes; 8A for parallel connection of channel 0 and 1 / channel 4 and 5
● for redundant control of a load No
Switching frequency
● with resistive load, max. 12.5 kHz
● with inductive load, max. 12.5 kHz; According to IEC 60947-5-1, DC-13
● on lamp load, max. 12.5 kHz
Total current of the outputs
● Current per channel, max. 5 A; see additional description in the manual
● Current per group, max. 8 A; see additional description in the manual
● Current per module, max. 16 A; see additional description in the manual
Total current of the outputs (per module)
horizontal installation
— up to 40 °C, max. 8 A
— up to 60 °C, max. 5 A
vertical installation
— up to 40 °C, max. 5 A
Cable length
● shielded, max. 1 000 m
● unshielded, max. 600 m
Isochronous mode
Bus cycle time (TDP), min. 250 µs
Interrupts/diagnostics/status information
Diagnostics function Yes
Substitute values connectable Yes
Alarms
● Diagnostic alarm Yes
● Maintenance interrupt Yes; maintenance alarm for switching cycle counter
Diagnoses
● Monitoring the supply voltage Yes
● Wire break No
● short-circuit Yes
● Group error Yes
Diagnostics indication LED
● RUN LED Yes; green LED
● ERROR LED Yes; red LED
● MAINT LED Yes; Yellow LED
● Monitoring of the supply voltage (PWR-LED) Yes; green LED
● Channel status display Yes; green LED
● for channel diagnostics Yes; red LED
● for module diagnostics Yes; red LED
Potential separation
Potential separation channels
● between the channels No
● between the channels, in groups of 4
● between the channels and backplane bus Yes
Isolation
Isolation tested with 707 V DC (type test)
Standards, approvals, certificates
Siemens Eco Profile (SEP) Siemens EcoTech
Suitable for safety functions No
Suitable for safety-related tripping of standard modules No
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 43.8 kg
— global warming potential, (during production) [CO2 eq] 9.5 kg
— global warming potential, (during operation) [CO2 eq] 34.5 kg
— global warming potential, (after end of life cycle) [CO2 eq]