Description
POWER SUPPLY-SITOP PSU8200/1AC/24VDC/5A-6EP33338SB000AY0
SITOP PSU8200 24 V/5 A stabilized power supply input: 120/230 V AC output: 24 V DC/5 A
INPUT type of the power supply network 1-phase AC
supply voltage at AC Automatic range selection
supply voltage 120 V/230 V
input voltage 1 at AC 85 ... 132 V
input voltage 2 at AC 170 ... 264 V
wide range input No
buffering time for rated value of the output current in the event of power failure minimum 35 ms
operating condition of the mains buffering at Vin = 120/230 V
line frequency 50/60 Hz
line frequency 47 ... 63 Hz
input current
● at rated input voltage 120 V 2.1 A
● at rated input voltage 230 V 1.2 A
current limitation of inrush current at 25 °C maximum 10 A
I2t value maximum 0.2 A²·s
fuse protection type T 3.15 A (not accessible)
fuse protection type in the feeder Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V
output
voltage curve at output Controlled, isolated DC voltage
output voltage at DC rated value 24 V
output voltage
● at output 1 at DC rated value 24 V
output voltage adjustable Yes; via potentiometer
adjustable output voltage 24 ... 28.8 V; max. 120 W
relative overall tolerance of the voltage 3 %
relative control precision of the output voltage
● on slow fluctuation of input voltage 0.1 %
● on slow fluctuation of ohm loading 0.2 %
residual ripple
● maximum 50 mV
voltage peak
● maximum 200 mV
display version for normal operation Green LED for 24 V OK
type of signal at output Relay contact (NO contact, rating 60 V DC/ 0.3 A) for “24 V OK”
behavior of the output voltage when switching on Overshoot of Vout approx. 3 %
response delay maximum 1.5 s
voltage increase time of the output voltage
● typical 30 ms
output current
● rated value 5 A
● rated range 0 ... 5 A; As of Ua>24 V: 4% [Ia]/V [Ua]; at Ue<100 V/<200 V: 80% Ia rated
supplied active power typical 120 W
short-term overload current
● at short-circuit during operation typical 15 A
duration of overloading capability for excess current
● at short-circuit during operation 25 ms
constant overload current
● on short-circuiting during the start-up typical 6 A
bridging of equipment Yes; switchable characteristic
number of parallel-switched equipment resources for increasing the power 2