SMPS by SIEMENS

POWER SUPPLY-SITOP PSU8200/1AC/24VDC/40A-6EP3337-8SB00-0AY0

DATA SHEET
In stock

Description

POWER SUPPLY-SITOP PSU8200/1AC/24VDC/40A-6EP3337-8SB00-0AY0

SITOP PSU8200 24 V/40 A stabilized power supply input: 120/230 V AC output: 24 V DC/40 A

INPUT type of the power supply network 1-phase and 2-phase AC

supply voltage at AC Automatic selection; startup starting from Ue ≥ 90/180 V

supply voltage 120 V/230 V

input voltage 1 at AC 85 ... 132 V

input voltage 2 at AC 170 ... 264 V

wide range input No

buffering time for rated value of the output current in the event of power failure minimum 25 ms

operating condition of the mains buffering at Vin = 230 V

line frequency 50/60 Hz

line frequency 45 ... 65 Hz

input current

● at rated input voltage 120 V 15 A

● at rated input voltage 230 V 9 A

current limitation of inrush current at 25 °C maximum 50 A

I2t value maximum 8 A²·s

fuse protection type Yes

fuse protection type in the feeder Recommended miniature circuit breaker at 1-phase operation: 16 A characteristic C; required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2421-4BA10 (120 V) or 3RV2411-1JA10 (230 V)

output

voltage curve at output Controlled, isolated DC voltage

output voltage at DC rated value 24 V

output voltage

● at output 1 at DC rated value 24 V

output voltage adjustable Yes; via potentiometer

adjustable output voltage 24 ... 28 V; max. 960 W

relative overall tolerance of the voltage 3 %

relative control precision of the output voltage

● on slow fluctuation of input voltage 0.1 %

● on slow fluctuation of ohm loading 0.1 %

residual ripple

● maximum 100 mV

● typical 50 mV

voltage peak

● maximum 240 mV

● typical 220 mV

display version for normal operation Green LED for 24 V OK; LED yellow for overload; LED red for short-circuit or latching shutdown

type of signal at output Relay contact (NO contact, rating 60 V DC/ 0.3 A) for “24 V OK”

behavior of the output voltage when switching on Overshoot of Vout approx. 3 %

response delay maximum 1.5 s

voltage increase time of the output voltage

● typical 30 ms

output current

● rated value 40 A

● rated range 0 ... 40 A; +60 ... +70 °C: Derating 3%/K

supplied active power typical 960 W

short-term overload current

● on short-circuiting during the start-up typical 120 A

● at short-circuit during operation typical 120 A

duration of overloading capability for excess current

● on short-circuiting during the start-up 25 ms

● at short-circuit during operation 25 ms

constant overload current

● on short-circuiting during the start-up typical 60 A

bridging of equipment Yes; switchable characteristic

number of parallel-switched equipment resources for increasing the power 2