S7-1200 G2 by siemens

CPU 1214C, DC/DC/DC, 14DI/10DO-6ES7214-1AH50-0XB0

INR 1
Learn more
In stock

Description

SIMATIC S7-1200 G2: compact CPU 1214C DC/DC/DC; power supply: DC 20.4-28.8 V DC; onboard I/O: 14x DI 24 V DC; 10 DO 24 V DC; memory: program 250 KB data: 750 KB, retentivity: 20 KB

General information

Product type designation CPU 1214C DC/DC/DC

Firmware version V4.1

● FW update possible Yes

Product function

● I&M data Yes; I&M0 to I&M3

● Isochronous mode Yes; For PROFINET only

● SysLog Yes

Engineering with

● Programming package STEP 7 V21 or higher

Supply voltage

Rated value (DC)

● 24 V DC Yes

permissible range, lower limit (DC) 20.4 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Input current

Current consumption (rated value) 145 mA; CPU only

Current consumption, max. 1 000 mA; CPU with all expansion modules

Inrush current, max. 12 A; at 28.8 V DC

I²t 0.5 A²·s

Output current

for backplane bus (5 V DC), max. 1 600 mA; Max. 5 V DC for SM and CM

Encoder supply

24 V encoder supply

● 24 V Yes; L+ minus 4 V DC min.

● Short-circuit protection Yes

● Output current, max. 400 mA

Power loss

Power loss, typ. 3.5 W

Storage

Work memory

● Integrated 1 000 kbyte

● integrated (for program) 250 kbyte

● integrated (for data) 750 kbyte

Load memory

● Integrated 8 Mbyte

● Plug-in (SIMATIC Memory Card), max. 32 Gbyte; with SIMATIC memory card

Backup

● present Yes

● maintenance-free Yes

● Without battery Yes

CPU processing times

for bit operations, typ. 37 ns; / instruction

for word operations, typ. 30 ns; / instruction

for floating point arithmetic, typ. 74 ns; / instruction

CPU-blocks

Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs

OB

● Number of free cycle OBs 100

● Number of time alarm OBs 20

● Number of delay alarm OBs 20

● Number of cyclic interrupt OBs 20; with minimum OB 3x cycle of 1 ms

● Number of process alarm OBs 50

● Number of DPV1 alarm OBs 3

● Number of isochronous mode OBs 1

● Number of startup OBs 100

● Number of asynchronous error OBs 4

● Number of synchronous error OBs 2

● Number of diagnostic alarm OBs 1

Data areas and their retentivity

Retentive data area (incl. timers, counters, flags), max. 20 kbyte

Flag

● Size, max. 8 kbyte; Size of bit memory address area

Local data

● per priority class, max. 64 kbyte; max. 16 KB per block

Address area

I/O address area

● Inputs 1 kbyte; All inputs are in the process image

● Outputs 1 kbyte; All outputs are in the process image

Process image

● Inputs, adjustable 1 kbyte

● Outputs, adjustable 1 kbyte

Hardware configuration

Number of modules per system, max. 10

● number of expansion boards (SB, CB, BB) 2

● number of signal modules (SM) 10; depends on the number of CMs

● number of communications modules (CM) 3

Time of day

Clock

● Hardware clock (real-time) Yes

● Backup time 480 h; Typical

● Deviation per day, max. 2 s; at 25 °C

Clock synchronization

● on Ethernet via NTP Yes

Digital inputs

Number of digital inputs 14; Integrated

● of which inputs usable for technological functions 8; HSC (High Speed Counting)

Sourcing/sinking input Yes

Number of simultaneously controllable inputs

all mounting positions

— up to 40 °C, max. 14

Input voltage

● Rated value (DC) 24 V

● for signal “0” 5 V DC or 0.5 mA

● for signal “1” 15 V DC at 2.5 mA

Input delay (for rated value of input voltage)

for standard inputs

— Parameterizable 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms

— at “0” to “1”, min. 0.1 µs

— at “0” to “1”, max. 20 µs

for interrupt inputs

— Parameterizable Yes

for technological functions

— Parameterizable single phase: 6 HSCs @ 100 kHz & 2 standard @ 30 kHz, quadrature phase: 6 HSCs @ 80 kHz & 2 standard @ 20 kHz

Cable length

● shielded, max. 500 m; 50 m for technological functions

● unshielded, max. 300 m; for technological functions: No

Digital outputs

Number of digital outputs 10; 20 kHz or 100 kHz

● of which high-speed outputs 4; 100 kHz (Qa.0 - Qa.3)

Limitation of inductive shutdown voltage to L+ (-40 V)

Switching capacity of the outputs

● with resistive load, max. 0.5 A

● on lamp load, max. 5 W

Output voltage

● for signal “0”, max. 0.1 V; with 10 kOhm load

● for signal “1”, min. 20 V

Output current

● for signal “1” rated value 0.5 A

● for signal “0” residual current, max. 10 µA

Output delay with resistive load

● “0” to “1”, max. 1 µs; of the pulse outputs (Qa.0 to Qa.3), max. 1.0 µs; of the standard outputs (Qa.4 to Qb.1), max. 50 µs;

● “1” to “0”, max. 3 µs; of the pulse outputs (Qa.0 to Qa.3), max. 3.0 µs; of the standard outputs (Qa.4 to Qb.1), max. 200 µs;

Switching frequency

● of the pulse outputs, with resistive load, max. 100 kHz; 100 kHz max. (Qa.0 - Qa.3), 20 kHz max. (Qa.4 to Qb.1)

Relay outputs

● Number of relay outputs 0

Cable length

● shielded, max. 500 m

● unshielded, max. 150 m

Analog inputs

Number of analog inputs 0

Analog outputs

Number of analog outputs 0

Encoder

Connectable encoders

● 2-wire sensor Yes

Interfaces

Number of PROFINET interfaces 1

1. Interface

Interface type PROFINET

Isolated Yes

automatic detection of transmission rate Yes

Autonegotiation Yes

Autocrossing Yes

Interface types

● RJ 45 (Ethernet) Yes; X1

— Transmission rate, max. 100 Mbit/s

● Number of ports 2

● integrated switch Yes

Protocols

● IP protocol Yes; IPv4

● PROFINET IO Controller Yes

● PROFINET IO device Yes

● SIMATIC communication Yes

● Open IE communication Yes; Optionally also encrypted

● Web server Yes

● Media redundancy Yes

PROFINET IO Controller

● Transmission rate, max. 100 Mbit/s

Services

— PG/OP communication Yes; encryption with TLS V1.3 pre-selected

— Isochronous mode Yes

— IRT Yes

— Dynamic Frame Packing (DFP) Yes

— PROFIenergy Yes; per user program

— Prioritized startup Yes

— Number of IO devices with prioritized startup, max. 16

— Number of connectable IO Devices, max. 31

— Of which IO devices with IRT, max. 31

— Number of connectable IO Devices for RT, max. 31

— of which in line, max. 31

— Number of IO Devices that can be simultaneously activated/deactivated, max. 8

— Updating time The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.

Update time for IRT

— for send cycle of 1 ms 1 ms to 16 ms

— for send cycle of 2 ms 2 ms to 32 ms

— for send cycle of 4 ms 4 ms to 64 ms

Update time for RT

— for send cycle of 1 ms 1 ms to 512 ms

— for send cycle of 2 ms 2 ms to 512 ms

— for send cycle of 4 ms 4 ms to 512 ms

PROFINET IO Device

Services

— PG/OP communication Yes; encryption with TLS V1.3 pre-selected

— Isochronous mode No

— IRT Yes

— Dynamic Frame Packing (DFP) No

— PROFIenergy Yes; per user program

— Prioritized startup Yes

— Shared device Yes

— Number of IO Controllers with shared device, max. 2

— Asset management record Yes

Protocols

PROFINET IO Yes

PROFIsafe No

PROFIBUS No

OPC UA Yes; OPC UA Server

AS-Interface No

Protocols (Ethernet)

● TCP/IP Yes

● DHCP Yes

● SNMP Yes

● DCP Yes

● LLDP Yes

Number of connections

● Number of connections, max. 128; via integrated interfaces of the CPU and connected CPs / CMs

● Number of connections reserved for ES/HMI/web 10

● Number of connections via integrated interfaces 88

● Number of S7 routing paths 16

Redundancy mode

● PROFINET system redundancy (S2) No

● PROFINET system redundancy (R1) No

Media redundancy

— MRP Yes; as MRP redundancy manager and/or MRP client

— MRP interconnection, supported Yes

— MRPD Yes; Requirement: IRT

— Number of stations in the ring, max. 50

SIMATIC communication

● PG/OP communication Yes; encryption with TLS V1.3 pre-selected

● S7 routing Yes

● S7 communication, as server Yes

● S7 communication, as client Yes; only PUT/GET

● User data per job, max. See online help (S7 communication, user data size)

Open IE communication

● TCP/IP Yes

— Data length, max. 64 kbyte

— several passive connections per port, supported Yes

● ISO-on-TCP (RFC1006) Yes

— Data length, max. 64 kbyte

● UDP Yes

— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast

● DHCP Yes

● DNS Yes

● SNMP Yes

● DCP Yes

● LLDP Yes

● encryption Yes; Optional

Web server

● supported Yes

● HTTPS Yes

● web API Yes

— Number of sessions, max. 30

— HTTP request body, max. 131 072 byte

● User-defined websites Yes

OPC UA

● Runtime license required Yes; “Basic” license required

● OPC UA Server Yes; data access (read, write, subscribe), method call, runtime license required

— Application authentication Yes

— Security policies available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss

— User authentication “anonymous” or by user name & password

— Number of sessions, max. 10

— Number of subscriptions per session, max. 5

— Sampling interval, min. 100 ms

— Publishing interval, min. 200 ms

— Number of server methods, max. 20

— Number of monitored items, recommended max. 1 000

— Number of server interfaces, max. 2

— Number of nodes for user-defined server interfaces, max. 2 000

Further protocols

● MODBUS Yes; MODBUS RTU/TCP

Communication functions

S7 communication

● supported Yes

● as server Yes

● As client Yes

● User data per job, max. See online help (S7 communication, user data size)

Number of connections

● overall PG Connections: 4 reserved; HMI Connections: 4 reserved / 82 max; S7 Connections: 78 max; Open User Connections: 78 max; Web Connections: 2 reserved / 80 max; Total Connections: 10 reserved / 88 max

S7 message functions

Number of login stations for message functions, max. 32

number of subscriptions, max. 250

number of tags/attributes for subscriptions, max. 2 000

Program alarms Yes

Number of configurable program messages, max. 5 000

Number of loadable program messages in RUN, max. 2 500

Number of simultaneously active program alarms

● Number of program alarms 600

● Number of alarms for system diagnostics 100

● Number of alarms for motion technology objects 160

Test commissioning functions

Status block Yes; Up to 8 simultaneously (in total across all ES clients)

Single step No

Profiling Yes

Status/control

● Status/control variable Yes

● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

● Number of variables, max.

— of which status variables, max. 200; per job

— of which control variables, max. 200; per job

Forcing

● Forcing Yes

● Forcing, variables Peripheral inputs/outputs

● Number of variables, max. 200

Diagnostic buffer

● present Yes

● Number of entries, max. 500

— of which powerfail-proof 100

Traces

● Number of configurable Traces 4

● Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information

Diagnostics indication LED

● RUN/STOP LED Yes

● ERROR LED Yes

● MAINT LED Yes

Supported technology objects

Motion Control Yes

● Number of available Motion Control resources for technology objects 800

● Required Motion Control resources

— per speed-controlled axis 40

— per positioning axis 80

— per synchronous axis 160

— per external encoder 80

— per output cam 20

— per cam track 160

— per probe 40

● Number of available Extended Motion Control resources for technology objects 40

● Required Extended Motion Control resources

— per cam (1 000 points and 50 segments) 2

— for each set of kinematics 30

● kinematics functions

— kinematics with up to 4 interpolating axes Yes

— kinematics with 5 or more interpolating axes No

— user-defined kinematics No

— SIMATIC Safe Kinematics No

● Positioning axis

— Number of positioning axes at motion control cycle of 4 ms (typical value) 10

— Number of positioning axes at motion control cycle of 8 ms (typical value) 10

Integrated Functions

Counter Yes

● Number of counters 8

● Counting frequency, max. 100 kHz; Ia.0 to Ia.5: 100 kHz (80 kHz in quadrature mode), Ia.6 to Ib.5: 30 kHz (20 kHz in quadrature mode)

Frequency measurement Yes

controlled positioning Yes

Number of position-controlled positioning axes, max. 8

Number of positioning axes via pulse-direction interface Up to 4 with SB 1222

PID controller Yes

Number of pulse outputs 8; individually assigned to CPU and Signal Board

Limit frequency (pulse) 100 kHz

Potential separation

Potential separation digital inputs

● Potential separation digital inputs Yes; field side to logic: 707 V DC (type test)

● between the channels No

● Number of potential groups 1

Potential separation digital outputs

● Potential separation digital outputs Yes

● between the channels No

● Number of potential groups 1

EMC

Interference immunity against discharge of static electricity

● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes

— Test voltage at air discharge 8 kV

— Test voltage at contact discharge 6 kV

Interference immunity to cable-borne interference

● Interference immunity on supply lines acc. to IEC 61000-4-4 Yes

● Interference immunity on signal cables acc. to IEC 61000-4-4 Yes

Interference immunity against voltage surge

● Interference immunity on supply lines acc. to IEC 61000-4-5 Yes

Interference immunity against conducted variable disturbance induced by high-frequency fields

● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 Yes

Emission of radio interference acc. to EN 55 011

● Limit class A, for use in industrial areas Yes; Group 1

● Limit class B, for use in residential areas Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011

Degree and class of protection

IP degree of protection IP20

Standards, approvals, certificates

Siemens Eco Profile (SEP) Siemens EcoTech

CE mark Yes

UL approval Yes

cULus Yes

FM approval No

RCM (formerly C-TICK) Yes

KC approval Yes

Marine approval Yes

Ecological footprint

● environmental product declaration Yes; type 2 acc. to ISO 14021

Global warming potential

— global warming potential, (total) [CO2 eq] 68 kg

— global warming potential, (during production) [CO2 eq] 14.4 kg

— global warming potential, (during operation) [CO2 eq] 54.2 kg

— global warming potential, (after end of life cycle) [CO2 eq]