Description
SIMATIC S7-1200 G2: compact CPU 1214C DC/DC/RLY; power supply: DC 20.4-28.8 V DC; onboard I/O: 14x DI 24 V DC; 10 DO relay 2 A; memory: program 250 KB data: 750 KB, retentivity: 20 KB
General information
Product type designation CPU 1214C DC/DC/Relay
Firmware version V4.1
● FW update possible Yes
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; For PROFINET only
● SysLog Yes
Engineering with
● Programming package STEP 7 V21 or higher
Supply voltage
Rated value (DC)
● 24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption (rated value) 245 mA; CPU only
Current consumption, max. 1 100 mA; CPU with all expansion modules
Inrush current, max. 12 A; at 28.8 V DC
I²t 0.5 A²·s
Output current
for backplane bus (5 V DC), max. 1 600 mA; Max. 5 V DC for SM and CM
Encoder supply
24 V encoder supply
● 24 V Yes; L+ minus 4 V DC min.
● Short-circuit protection Yes
● Output current, max. 400 mA
Power loss
Power loss, typ. 3.5 W
Storage
Work memory
● Integrated 1 000 kbyte
● integrated (for program) 250 kbyte
● integrated (for data) 750 kbyte
Load memory
● Integrated 8 Mbyte
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte; with SIMATIC memory card
Backup
● present Yes
● maintenance-free Yes
● without battery Yes
CPU processing times
for bit operations, typ. 37 ns; / instruction
for word operations, typ. 30 ns; / instruction
for floating point arithmetic, typ. 74 ns; / instruction
CPU-blocks
Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs
OB
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; with minimum OB 3x cycle of 1 ms
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 1
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 20 kbyte
Flag
● Size, max. 8 kbyte; Size of bit memory address area
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
I/O address area
● Inputs 1 kbyte; All inputs are in the process image
● Outputs 1 kbyte; All outputs are in the process image
Process image
● Inputs, adjustable 1 kbyte
● Outputs, adjustable 1 kbyte
Hardware configuration
Number of modules per system, max. 10
● number of expansion boards (SB, CB, BB) 2
● number of signal modules (SM) 10; depends on the number of CMs
● number of communications modules (CM) 3
Time of day
Clock
● Hardware clock (real-time) Yes
● Backup time 480 h; Typical
● Deviation per day, max. 2 s; at 25 °C
Clock synchronization
● on Ethernet via NTP Yes
Digital inputs
Number of digital inputs 14; Integrated
● of which inputs usable for technological functions 8; HSC (High Speed Counting)
Sourcing/sinking input Yes
Number of simultaneously controllable inputs
all mounting positions
— up to 40 °C, max. 14
Input voltage
● Rated value (DC) 24 V
● for signal “0” 5 V DC or 0.5 mA
● for signal “1” 15 V DC at 2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms
— at “0” to “1”, min. 0.1 µs
— at “0” to “1”, max. 20 µs
for interrupt inputs
— parameterizable Yes
for technological functions
— parameterizable single phase: 6 HSCs @ 100 kHz & 2 standard @ 30 kHz, quadrature phase: 6 HSCs @ 80 kHz & 2 standard @ 20 kHz
Cable length
● shielded, max. 500 m; 50 m for technological functions
● unshielded, max. 300 m; for technological functions: No
Digital outputs
Number of digital outputs 10; Relays
Switching capacity of the outputs
● with resistive load, max. 2 A
● on lamp load, max. 30 W with DC, 200 W with AC
Output delay with resistive load
● “0” to “1”, max. 10 ms; max.
● “1” to “0”, max. 10 ms; max.
Switching frequency
● of the pulse outputs, with resistive load, max. Not recommended
Relay outputs
● Number of relay outputs 10
● Number of operating cycles, max. mechanically 10 million, at rated load voltage 100 000
Cable length
● shielded, max. 500 m
● unshielded, max. 150 m
Analog inputs
Number of analog inputs 0
Analog outputs
Number of analog outputs 0
Encoder
Connectable encoders
● 2-wire sensor Yes
Interfaces
Number of PROFINET interfaces 1
1. Interface
Interface type PROFINET
Isolated Yes
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface types
● RJ 45 (Ethernet) Yes; X1
— Transmission rate, max. 100 Mbit/s
● Number of ports 2
● integrated switch Yes
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy Yes
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
Services
— PG/OP communication Yes; encryption with TLS V1.3 pre-selected
— Isochronous mode Yes
— IRT Yes
— Dynamic Frame Packing (DFP) Yes
— PROFIenergy Yes; per user program
— Prioritized startup Yes
— Number of IO devices with prioritized startup, max. 16
— Number of connectable IO Devices, max. 31
— Of which IO devices with IRT, max. 31
— Number of connectable IO Devices for RT, max. 31
— of which in line, max. 31
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8
— Updating time The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
Update time for IRT
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
Update time for RT
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communication Yes; encryption with TLS V1.3 pre-selected
— Isochronous mode No
— IRT Yes
— Dynamic Frame Packing (DFP) No
— PROFIenergy Yes; per user program
— Prioritized startup Yes
— Shared device Yes
— Number of IO Controllers with shared device, max. 2
— Asset management record Yes
Protocols
Supports protocol for PROFINET IO Yes
PROFIsafe No
PROFIBUS No
OPC UA Yes; OPC UA Server
AS-Interface No
Protocols (Ethernet)
● TCP/IP Yes
● DHCP Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
Number of connections
● Number of connections, max. 128; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for ES/HMI/web 10
● Number of connections via integrated interfaces 88
● Number of S7 routing paths 16
Redundancy mode
● PROFINET system redundancy (S2) No
● PROFINET system redundancy (R1) No
Media redundancy
— MRP Yes; as MRP redundancy manager and/or MRP client
— MRP interconnection, supported Yes
— MRPD Yes; Requirement: IRT
— Number of stations in the ring, max. 50
SIMATIC communication
● PG/OP communication Yes; encryption with TLS V1.3 pre-selected
● S7 routing Yes
● S7 communication, as server Yes
● S7 communication, as client Yes; only PUT/GET
● User data per job, max. See online help (S7 communication, user data size)
Open IE communication
● TCP/IP Yes
— Data length, max. 64 kbyte
— several passive connections per port, supported Yes
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 64 kbyte
● UDP Yes
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
● DHCP Yes
● DNS Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
● Encryption Yes; Optional
Web server
● supported Yes
● HTTPS Yes
● web API Yes
— Number of sessions, max. 30
— HTTP request body, max. 131 072 byte
● User-defined websites Yes
Specifications
| - | - |
|---|---|
| - | - |