S7-1200 G2 by SIEMENS

CPU 1214C, DC/DC/RLY, 14DI/10DO - 6ES7214-1HH50-0XB0

INR 1
DATASHEET
In stock

Description

SIMATIC S7-1200 G2: compact CPU 1214C DC/DC/RLY; power supply: DC 20.4-28.8 V DC; onboard I/O: 14x DI 24 V DC; 10 DO relay 2 A; memory: program 250 KB data: 750 KB, retentivity: 20 KB

General information

Product type designation CPU 1214C DC/DC/Relay

Firmware version V4.1

● FW update possible Yes

Product function

● I&M data Yes; I&M0 to I&M3

● Isochronous mode Yes; For PROFINET only

● SysLog Yes

Engineering with

● Programming package STEP 7 V21 or higher

Supply voltage

Rated value (DC)

● 24 V DC Yes

permissible range, lower limit (DC) 20.4 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Input current

Current consumption (rated value) 245 mA; CPU only

Current consumption, max. 1 100 mA; CPU with all expansion modules

Inrush current, max. 12 A; at 28.8 V DC

I²t 0.5 A²·s

Output current

for backplane bus (5 V DC), max. 1 600 mA; Max. 5 V DC for SM and CM

Encoder supply

24 V encoder supply

● 24 V Yes; L+ minus 4 V DC min.

● Short-circuit protection Yes

● Output current, max. 400 mA

Power loss

Power loss, typ. 3.5 W

Storage

Work memory

● Integrated 1 000 kbyte

● integrated (for program) 250 kbyte

● integrated (for data) 750 kbyte

Load memory

● Integrated 8 Mbyte

● Plug-in (SIMATIC Memory Card), max. 32 Gbyte; with SIMATIC memory card

Backup

● present Yes

● maintenance-free Yes

● without battery Yes

CPU processing times

for bit operations, typ. 37 ns; / instruction

for word operations, typ. 30 ns; / instruction

for floating point arithmetic, typ. 74 ns; / instruction

CPU-blocks

Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs

OB

● Number of free cycle OBs 100

● Number of time alarm OBs 20

● Number of delay alarm OBs 20

● Number of cyclic interrupt OBs 20; with minimum OB 3x cycle of 1 ms

● Number of process alarm OBs 50

● Number of DPV1 alarm OBs 3

● Number of isochronous mode OBs 1

● Number of startup OBs 100

● Number of asynchronous error OBs 4

● Number of synchronous error OBs 2

● Number of diagnostic alarm OBs 1

Data areas and their retentivity

Retentive data area (incl. timers, counters, flags), max. 20 kbyte

Flag

● Size, max. 8 kbyte; Size of bit memory address area

Local data

● per priority class, max. 64 kbyte; max. 16 KB per block

Address area

I/O address area

● Inputs 1 kbyte; All inputs are in the process image

● Outputs 1 kbyte; All outputs are in the process image

Process image

● Inputs, adjustable 1 kbyte

● Outputs, adjustable 1 kbyte

Hardware configuration

Number of modules per system, max. 10

● number of expansion boards (SB, CB, BB) 2

● number of signal modules (SM) 10; depends on the number of CMs

● number of communications modules (CM) 3

Time of day

Clock

● Hardware clock (real-time) Yes

● Backup time 480 h; Typical

● Deviation per day, max. 2 s; at 25 °C

Clock synchronization

● on Ethernet via NTP Yes

Digital inputs

Number of digital inputs 14; Integrated

● of which inputs usable for technological functions 8; HSC (High Speed Counting)

Sourcing/sinking input Yes

Number of simultaneously controllable inputs

all mounting positions

— up to 40 °C, max. 14

Input voltage

● Rated value (DC) 24 V

● for signal “0” 5 V DC or 0.5 mA

● for signal “1” 15 V DC at 2.5 mA

Input delay (for rated value of input voltage)

for standard inputs

— parameterizable 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms

— at “0” to “1”, min. 0.1 µs

— at “0” to “1”, max. 20 µs

for interrupt inputs

— parameterizable Yes

for technological functions

— parameterizable single phase: 6 HSCs @ 100 kHz & 2 standard @ 30 kHz, quadrature phase: 6 HSCs @ 80 kHz & 2 standard @ 20 kHz

Cable length

● shielded, max. 500 m; 50 m for technological functions

● unshielded, max. 300 m; for technological functions: No

Digital outputs

Number of digital outputs 10; Relays

Switching capacity of the outputs

● with resistive load, max. 2 A

● on lamp load, max. 30 W with DC, 200 W with AC

Output delay with resistive load

● “0” to “1”, max. 10 ms; max.

● “1” to “0”, max. 10 ms; max.

Switching frequency

● of the pulse outputs, with resistive load, max. Not recommended

Relay outputs

● Number of relay outputs 10

● Number of operating cycles, max. mechanically 10 million, at rated load voltage 100 000

Cable length

● shielded, max. 500 m

● unshielded, max. 150 m

Analog inputs

Number of analog inputs 0

Analog outputs

Number of analog outputs 0

Encoder

Connectable encoders

● 2-wire sensor Yes

Interfaces

Number of PROFINET interfaces 1

1. Interface

Interface type PROFINET

Isolated Yes

automatic detection of transmission rate Yes

Autonegotiation Yes

Autocrossing Yes

Interface types

● RJ 45 (Ethernet) Yes; X1

— Transmission rate, max. 100 Mbit/s

● Number of ports 2

● integrated switch Yes

Protocols

● IP protocol Yes; IPv4

● PROFINET IO Controller Yes

● PROFINET IO Device Yes

● SIMATIC communication Yes

● Open IE communication Yes; Optionally also encrypted

● Web server Yes

● Media redundancy Yes

PROFINET IO Controller

● Transmission rate, max. 100 Mbit/s

Services

— PG/OP communication Yes; encryption with TLS V1.3 pre-selected

— Isochronous mode Yes

— IRT Yes

— Dynamic Frame Packing (DFP) Yes

— PROFIenergy Yes; per user program

— Prioritized startup Yes

— Number of IO devices with prioritized startup, max. 16

— Number of connectable IO Devices, max. 31

— Of which IO devices with IRT, max. 31

— Number of connectable IO Devices for RT, max. 31

— of which in line, max. 31

— Number of IO Devices that can be simultaneously activated/deactivated, max. 8

— Updating time The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.

Update time for IRT

— for send cycle of 1 ms 1 ms to 16 ms

— for send cycle of 2 ms 2 ms to 32 ms

— for send cycle of 4 ms 4 ms to 64 ms

Update time for RT

— for send cycle of 1 ms 1 ms to 512 ms

— for send cycle of 2 ms 2 ms to 512 ms

— for send cycle of 4 ms 4 ms to 512 ms

PROFINET IO Device

Services

— PG/OP communication Yes; encryption with TLS V1.3 pre-selected

— Isochronous mode No

— IRT Yes

— Dynamic Frame Packing (DFP) No

— PROFIenergy Yes; per user program

— Prioritized startup Yes

— Shared device Yes

— Number of IO Controllers with shared device, max. 2

— Asset management record Yes

Protocols

Supports protocol for PROFINET IO Yes

PROFIsafe No

PROFIBUS No

OPC UA Yes; OPC UA Server

AS-Interface No

Protocols (Ethernet)

● TCP/IP Yes

● DHCP Yes

● SNMP Yes

● DCP Yes

● LLDP Yes

Number of connections

● Number of connections, max. 128; via integrated interfaces of the CPU and connected CPs / CMs

● Number of connections reserved for ES/HMI/web 10

● Number of connections via integrated interfaces 88

● Number of S7 routing paths 16

Redundancy mode

● PROFINET system redundancy (S2) No

● PROFINET system redundancy (R1) No

Media redundancy

— MRP Yes; as MRP redundancy manager and/or MRP client

— MRP interconnection, supported Yes

— MRPD Yes; Requirement: IRT

— Number of stations in the ring, max. 50

SIMATIC communication

● PG/OP communication Yes; encryption with TLS V1.3 pre-selected

● S7 routing Yes

● S7 communication, as server Yes

● S7 communication, as client Yes; only PUT/GET

● User data per job, max. See online help (S7 communication, user data size)

Open IE communication

● TCP/IP Yes

— Data length, max. 64 kbyte

— several passive connections per port, supported Yes

● ISO-on-TCP (RFC1006) Yes

— Data length, max. 64 kbyte

● UDP Yes

— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast

● DHCP Yes

● DNS Yes

● SNMP Yes

● DCP Yes

● LLDP Yes

● Encryption Yes; Optional

Web server

● supported Yes

● HTTPS Yes

● web API Yes

— Number of sessions, max. 30

— HTTP request body, max. 131 072 byte

● User-defined websites Yes

Specifications

--
--